2005Anesthesia & AnalgesiaRequires access

A Single Adrenocorticotropic Hormone Stimulation Test Does Not Reveal Adrenal Insufficiency in Septic Shock

Pekka Loisa, Ari Uusaro, Esko Ruokonen

Open publisher page 65 citations

Abstract

In Brief The diagnosis of adrenocortical insufficiency in critically ill patients is complex. The adrenocorticotropic hormone (ACTH) stimulation test is a widely accepted method for assessing the adequacy of adrenal function in intensive care units, but it is possible that there may be wide variations in responses to the test over a short period of time. In this prospective study, we investigated the reproducibility of the ACTH stimulation test in 20 patients with sepsis, in 20 patients with septic shock, and in 20 critically ill patients without sepsis. Two consecutive ACTH stimulation tests were performed within 24 h after intensive care unit admission or at the onset of sepsis. In patients without sepsis there was good correlation between ACTH responses on days 1 and 2 (Pearson's correlation coefficient, 0.689; P = 0.001). In contrast, in patients with septic shock no correlation was observed between the two ACTH responses (Pearson's correlation coefficient, 0.401; P = 0.080). We conclude that the results of the ACTH stimulation tests are poorly reproducible in septic shock and a single ACTH stimulation test may not be the best method to diagnose adrenal insufficiency in these patients. IMPLICATIONS: In this prospective study two consecutive adrenocorticotropic hormone (ACTH) stimulation tests were performed in 60 critically ill patients. In a subgroup of septic shock patients the test results were poorly reproducible. This suggests that the ACTH stimulation test is not a sensitive method to diagnose adrenal insufficiency in septic shock patients.

About this research paper

What this paper is about

In Brief The diagnosis of adrenocortical insufficiency in critically ill patients is complex. The adrenocorticotropic hormone (ACTH) stimulation test is a widely accepted method for assessing the adequacy of adrenal function in intensive care units, but it is possible that there may be wide variations in responses to the test over a short period of time. In this prospective study, we investigated the reproducibility of the ACTH stimulation test in 20 patients with sepsis, in 20 patients with septic shock, and in 20 critically ill patients without sepsis. Two consecutive ACTH stimulation tests were performed within 24 h after intensive care unit admission or at the onset of sepsis. In patients without sepsis there was good correlation between ACTH responses on days 1 and 2 (Pearson's correlation coefficient, 0.689; P = 0.001). In contrast, in patients with septic shock no correlation was observed between the two ACTH responses (Pearson's correlation coefficient, 0.401; P = 0.080). We conclude that the results of the ACTH stimulation tests are poorly reproducible in septic shock and a single ACTH stimulation test may not be the best method to diagnose adrenal insufficiency in these patients. IMPLICATIONS: In this prospective study two consecutive adrenocorticotropic hormone (ACTH) stimulation tests were performed in 60 critically ill patients. In a subgroup of septic shock patients the test results were poorly reproducible. This suggests that the ACTH stimulation test is not a sensitive method to diagnose adrenal insufficiency in septic shock patients.

Why it matters

OpenAlex reports 65 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In Brief The diagnosis of adrenocortical insufficiency in critically ill patients is complex. The adrenocorticotropic hormone (ACTH) stimulation test is a widely accepted method for assessing the adequacy of adrenal function in intensive care units, but it is possible that there may be wide variations in responses to the test over a short period of time. In this prospective study, we investigated the reproducibility of the ACTH stimulation test in 20 patients with sepsis, in 20 patients with septic shock, and in 20 critically ill patients without sepsis. Two consecutive ACTH stimulation tests were performed within 24 h after intensive care unit admission or at the onset of sepsis. In patients without sepsis there was good correlation between ACTH responses on days 1 and 2 (Pearson's correlation coefficient, 0.689; P = 0.001). In contrast, in patients with septic shock no correlation was observed between the two ACTH responses (Pearson's correlation coefficient, 0.401; P = 0.080). We conclude that the results of the ACTH stimulation tests are poorly reproducible in septic shock and a single ACTH stimulation test may not be the best method to diagnose adrenal insufficiency in these patients. IMPLICATIONS: In this prospective study two consecutive adrenocorticotropic hormone (ACTH) stimulation tests were performed in 60 critically ill patients. In a subgroup of septic shock patients the test results were poorly reproducible. This suggests that the ACTH stimulation test is not a sensitive method to diagnose adrenal insufficiency in septic shock patients.

Key concepts: Adrenocorticotropic hormone, Adrenal insufficiency, Septic shock, Medicine, Stimulation, ACTH stimulation test, Shock (circulatory), Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
A Single Adrenocorticotropic Hormone Stimulation Test Does Not Reveal Adrenal Insufficiency in Septic Shock — Research Paper | ScholarLens