2010Medicinski pregledRequires access

Analysis of anaerobic capacity in rowers using Wingate test on cycle and rowing ergometer

Aleksandar Klašnja, Otto Barak, Jelena Popadić-Gaćeša, Miodrag Drapšin, Aleksandar Knežević, Nikola Grujić

Open publisher page 8 citations

Abstract

The 30-s all-out Wingate test has been used in athletes of all sport specialties to measure the capacity for short duration, high power output while cycling. The aim of this study was to establish differences in measuring anaerobic capacity between the classic Wingate test on a cycling ergometer and the modified Wingate test on a rowing ergometer in rowers. A group of20 rowers was tested by both the cycle and rowing ergometers during 30s of maximum power to test anaerobic capacity and to make correlation between these tests. The parameters measured were the peak power and mean power. The peak power on the cycling ergometer was 475 +/- 75.1W and 522.4 +/- 81W (p < 0.05) on the rowing ergometer. The mean power on the cycling ergometer and the rowing ergometer was 344.4 +/- 51.1W and 473.7W +/- 67.2, (p < 0.05) respectively. The maximum values were achieved at the same time on both ergometers, but remained on the higher level till the end of the test on the rowing ergometer. By correlating the anaerobic parameters of the classic Wingate test and a modified Wingate test on the rowing ergometer a significant positive correlation was detected in the peak power (r = 0.63, p < 0.05) as well as in the mean power (r = 0.65, p < 0.05). The results show that the rowers achieved better results of the anaerobic parameters on the rowing ergometer compared to the cycling ergometer due to a better mechanical efficiency. It is concluded that the modified Wingate test on the rowing ergometer can be used in rowers for testing their anaerobic capacity as a sport specific test ergometer since it provides more precise results.

About this research paper

What this paper is about

The 30-s all-out Wingate test has been used in athletes of all sport specialties to measure the capacity for short duration, high power output while cycling. The aim of this study was to establish differences in measuring anaerobic capacity between the classic Wingate test on a cycling ergometer and the modified Wingate test on a rowing ergometer in rowers. A group of20 rowers was tested by both the cycle and rowing ergometers during 30s of maximum power to test anaerobic capacity and to make correlation between these tests. The parameters measured were the peak power and mean power. The peak power on the cycling ergometer was 475 +/- 75.1W and 522.4 +/- 81W (p < 0.05) on the rowing ergometer. The mean power on the cycling ergometer and the rowing ergometer was 344.4 +/- 51.1W and 473.7W +/- 67.2, (p < 0.05) respectively. The maximum values were achieved at the same time on both ergometers, but remained on the higher level till the end of the test on the rowing ergometer. By correlating the anaerobic parameters of the classic Wingate test and a modified Wingate test on the rowing ergometer a significant positive correlation was detected in the peak power (r = 0.63, p < 0.05) as well as in the mean power (r = 0.65, p < 0.05). The results show that the rowers achieved better results of the anaerobic parameters on the rowing ergometer compared to the cycling ergometer due to a better mechanical efficiency. It is concluded that the modified Wingate test on the rowing ergometer can be used in rowers for testing their anaerobic capacity as a sport specific test ergometer since it provides more precise results.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The 30-s all-out Wingate test has been used in athletes of all sport specialties to measure the capacity for short duration, high power output while cycling. The aim of this study was to establish differences in measuring anaerobic capacity between the classic Wingate test on a cycling ergometer and the modified Wingate test on a rowing ergometer in rowers. A group of20 rowers was tested by both the cycle and rowing ergometers during 30s of maximum power to test anaerobic capacity and to make correlation between these tests. The parameters measured were the peak power and mean power. The peak power on the cycling ergometer was 475 +/- 75.1W and 522.4 +/- 81W (p < 0.05) on the rowing ergometer. The mean power on the cycling ergometer and the rowing ergometer was 344.4 +/- 51.1W and 473.7W +/- 67.2, (p < 0.05) respectively. The maximum values were achieved at the same time on both ergometers, but remained on the higher level till the end of the test on the rowing ergometer. By correlating the anaerobic parameters of the classic Wingate test and a modified Wingate test on the rowing ergometer a significant positive correlation was detected in the peak power (r = 0.63, p < 0.05) as well as in the mean power (r = 0.65, p < 0.05). The results show that the rowers achieved better results of the anaerobic parameters on the rowing ergometer compared to the cycling ergometer due to a better mechanical efficiency. It is concluded that the modified Wingate test on the rowing ergometer can be used in rowers for testing their anaerobic capacity as a sport specific test ergometer since it provides more precise results.

Key concepts: Rowing, Medicine, Anaerobic exercise, Wingate test, Cycle ergometer, Physical therapy, Test (biology), Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of anaerobic capacity in rowers using Wingate test on cycle and rowing ergometer — Research Paper | ScholarLens