2013•Unpublished venueRequires access

Assessing the energy savings potential in public buildings through retrofit measures in tropical climates — A case study in Mauritius

Oumesh Kumar Mohit, Vishwamitra Oree

Open publisher page 5 citations

Abstract

Until recently in Mauritius, the energy efficiency aspect was largely overlooked during the design of buildings. Retrofitting of existing buildings therefore presents significant opportunities for the country to curtail its energy consumption. In this study, a number of energy-saving retrofit measures are considered for a ten-level building at the University of Mauritius. An energy audit was first conducted in the building to identify potential areas of energy inefficiency. A comprehensive analysis of the collected data was then performed to select the most cost-effective retrofit options for each identified area. The proposed retrofit measures consisted mainly of actions carried out on the air conditioning system, lighting or building envelope. Subsequently, the forecasted energy savings caused by each of the recommended measures was estimated. Calculations showed that implementation of those measures would result in a reduction in the annual energy consumption of about 33% for lighting and 37% for air conditioning. The retrofit measures would have a payback period of 1.2 and 6.6 years respectively. The results further revealed that a 13% decrease in the monthly charge would be achieved if the recommended measures to reduce the peak demand charge were applied.

About this research paper

What this paper is about

Until recently in Mauritius, the energy efficiency aspect was largely overlooked during the design of buildings. Retrofitting of existing buildings therefore presents significant opportunities for the country to curtail its energy consumption. In this study, a number of energy-saving retrofit measures are considered for a ten-level building at the University of Mauritius. An energy audit was first conducted in the building to identify potential areas of energy inefficiency. A comprehensive analysis of the collected data was then performed to select the most cost-effective retrofit options for each identified area. The proposed retrofit measures consisted mainly of actions carried out on the air conditioning system, lighting or building envelope. Subsequently, the forecasted energy savings caused by each of the recommended measures was estimated. Calculations showed that implementation of those measures would result in a reduction in the annual energy consumption of about 33% for lighting and 37% for air conditioning. The retrofit measures would have a payback period of 1.2 and 6.6 years respectively. The results further revealed that a 13% decrease in the monthly charge would be achieved if the recommended measures to reduce the peak demand charge were applied.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Until recently in Mauritius, the energy efficiency aspect was largely overlooked during the design of buildings. Retrofitting of existing buildings therefore presents significant opportunities for the country to curtail its energy consumption. In this study, a number of energy-saving retrofit measures are considered for a ten-level building at the University of Mauritius. An energy audit was first conducted in the building to identify potential areas of energy inefficiency. A comprehensive analysis of the collected data was then performed to select the most cost-effective retrofit options for each identified area. The proposed retrofit measures consisted mainly of actions carried out on the air conditioning system, lighting or building envelope. Subsequently, the forecasted energy savings caused by each of the recommended measures was estimated. Calculations showed that implementation of those measures would result in a reduction in the annual energy consumption of about 33% for lighting and 37% for air conditioning. The retrofit measures would have a payback period of 1.2 and 6.6 years respectively. The results further revealed that a 13% decrease in the monthly charge would be achieved if the recommended measures to reduce the peak demand charge were applied.

Key concepts: Retrofitting, Payback period, Air conditioning, Energy consumption, Inefficiency, Building envelope, Efficient energy use, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessing the energy savings potential in public buildings through retrofit measures in tropical climates — A case study in Mauritius — Research Paper | ScholarLens