1960Unpublished venueOpen access

COULOMETRIC TITRATION OF URANIUM IN NITRIC ACID SOLUTIONS

M.O. Fulda

Open full text 0 citations

Abstract

A coulometric titration method was developed for the determination of uranium in HNO/sub 3/ solutions. Uranium was reduced to the (IV) state and was titrated with electrolytically generated cerium(IV). The colorimetric end point was detected automatically by a photometric technique. Interference from nitrate was eliminated by the addition of urea to the titration medium. The coefficient of variation for the analysis of uranium was 3.2% for 1-mg samples and 0.3% for 100-mg samples. With the addition of urea as much as 4.5 milliequivalents of nitric acid in a 1- to 3-ml sample was tolerated. (auth)

About this research paper

What this paper is about

A coulometric titration method was developed for the determination of uranium in HNO/sub 3/ solutions. Uranium was reduced to the (IV) state and was titrated with electrolytically generated cerium(IV). The colorimetric end point was detected automatically by a photometric technique. Interference from nitrate was eliminated by the addition of urea to the titration medium. The coefficient of variation for the analysis of uranium was 3.2% for 1-mg samples and 0.3% for 100-mg samples. With the addition of urea as much as 4.5 milliequivalents of nitric acid in a 1- to 3-ml sample was tolerated. (auth)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A coulometric titration method was developed for the determination of uranium in HNO/sub 3/ solutions. Uranium was reduced to the (IV) state and was titrated with electrolytically generated cerium(IV). The colorimetric end point was detected automatically by a photometric technique. Interference from nitrate was eliminated by the addition of urea to the titration medium. The coefficient of variation for the analysis of uranium was 3.2% for 1-mg samples and 0.3% for 100-mg samples. With the addition of urea as much as 4.5 milliequivalents of nitric acid in a 1- to 3-ml sample was tolerated. (auth)

Key concepts: Titration, Uranium, Nitric acid, Coulometry, Chemistry, Urea, Nitrate, Cerium

Related papers

Back to paper searchBrowse research topicsOriginal source
COULOMETRIC TITRATION OF URANIUM IN NITRIC ACID SOLUTIONS — Research Paper | ScholarLens