Thermal stability of retained austenite in Cr–Ni weld metals at low temperatures
Haiyan Qiu, Jingang Qi, Linning Wang, Fuxing Yin, Kazuya Hiraoka
Abstract
Haiyan Qiu, Jingang Qi, Linning Wang, Fuxing Yin, Kazuya Hiraoka
Abstract
As environmental temperature decreases, the amount of retained austenite is more likely to greatly reduce due to the thermal austenite–martensite transformation caused by the decreased thermal stability of retained austenite, probably making its amount lower than the required content. In the present study, the thermal stability of retained austenite in Cr–Ni weld metals was investigated to see whether sufficient retained austenite can be maintained at low temperatures. The specific experimental procedure is as follows: briefly, the samples were cooled in turn from room temperature to 0, −20, −40, −60, −80, −100 and −196°C; the amount of retained austenite at the above temperatures was measured using X-ray diffraction. Through investigating the dependence of the content of retained austenite on temperature, it was revealed that when the content of retained austenite is <20, retained austenite can be maintained until −196°C.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
As environmental temperature decreases, the amount of retained austenite is more likely to greatly reduce due to the thermal austenite–martensite transformation caused by the decreased thermal stability of retained austenite, probably making its amount lower than the required content. In the present study, the thermal stability of retained austenite in Cr–Ni weld metals was investigated to see whether sufficient retained austenite can be maintained at low temperatures. The specific experimental procedure is as follows: briefly, the samples were cooled in turn from room temperature to 0, −20, −40, −60, −80, −100 and −196°C; the amount of retained austenite at the above temperatures was measured using X-ray diffraction. Through investigating the dependence of the content of retained austenite on temperature, it was revealed that when the content of retained austenite is <20, retained austenite can be maintained until −196°C.
Key concepts: Austenite, Materials science, Metallurgy, Martensite, Thermal stability, Welding, Thermal, Microstructure