2012Laser PhysicsRequires access

High-power and efficiency continuous-wave operation of a-cut Ho:YAP laser at room temperature

Yingjie Shen, Baoquan Yao, Xiaoming Duan, Y. L. Ju, You Wang

Open publisher page 5 citations

Abstract

We report the continuous-wave (CW) operation of a room-temperature a-cut Ho:YAP laser resonantly end-pumped by a diode-pumped Tm:YLF laser at 1.91 μm. A maximum CW output power of 14.6 W at 2118.7 nm for a-oriented Ho:YAP was obtained, corresponding to the slope efficiency of 69.35% and optical-to-optical conversion efficiency of 63.04% with respect to absorbed pump power. The laser operated at a single mode (TEM00) with the beam quality factor of M 2 ∼ 1.51.

About this research paper

What this paper is about

We report the continuous-wave (CW) operation of a room-temperature a-cut Ho:YAP laser resonantly end-pumped by a diode-pumped Tm:YLF laser at 1.91 μm. A maximum CW output power of 14.6 W at 2118.7 nm for a-oriented Ho:YAP was obtained, corresponding to the slope efficiency of 69.35% and optical-to-optical conversion efficiency of 63.04% with respect to absorbed pump power. The laser operated at a single mode (TEM00) with the beam quality factor of M 2 ∼ 1.51.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We report the continuous-wave (CW) operation of a room-temperature a-cut Ho:YAP laser resonantly end-pumped by a diode-pumped Tm:YLF laser at 1.91 μm. A maximum CW output power of 14.6 W at 2118.7 nm for a-oriented Ho:YAP was obtained, corresponding to the slope efficiency of 69.35% and optical-to-optical conversion efficiency of 63.04% with respect to absorbed pump power. The laser operated at a single mode (TEM00) with the beam quality factor of M 2 ∼ 1.51.

Key concepts: Continuous wave, Materials science, Slope efficiency, Laser, Energy conversion efficiency, Optics, Laser beam quality, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
High-power and efficiency continuous-wave operation of a-cut Ho:YAP laser at room temperature — Research Paper | ScholarLens