1998Pacing and Clinical ElectrophysiologyRequires access

Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins

Jean Claude Daubert, Philippe Ritter, Hervé Breton, Daniel Gras, Christophe Leclercq, Arnaud Lazarus, J Múgica, PHILIPPE MABO, Serge Cazeau

Open publisher page 348 citations

Abstract

This paper describes a preliminary experiment-conducted jointly by 2 centers-of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in patients with severe LV dysfunction and drug-refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15 +/- 0.7 V acute pacing threshold and 11.8 +/- 5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53.3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero-lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 +/- 0.2 vs 1.8 +/- 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 +/- 4.5 mV vs 9.3 +/- 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow-up (10.2 +/- 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 +/- 0.7 V and a R wave amplitude of 10.7 +/- 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long-term results.

About this research paper

What this paper is about

This paper describes a preliminary experiment-conducted jointly by 2 centers-of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in patients with severe LV dysfunction and drug-refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15 +/- 0.7 V acute pacing threshold and 11.8 +/- 5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53.3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero-lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 +/- 0.2 vs 1.8 +/- 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 +/- 4.5 mV vs 9.3 +/- 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow-up (10.2 +/- 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 +/- 0.7 V and a R wave amplitude of 10.7 +/- 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long-term results.

Why it matters

OpenAlex reports 348 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes a preliminary experiment-conducted jointly by 2 centers-of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in patients with severe LV dysfunction and drug-refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15 +/- 0.7 V acute pacing threshold and 11.8 +/- 5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53.3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero-lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 +/- 0.2 vs 1.8 +/- 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 +/- 4.5 mV vs 9.3 +/- 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow-up (10.2 +/- 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 +/- 0.7 V and a R wave amplitude of 10.7 +/- 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long-term results.

Key concepts: Medicine, Coronary sinus, Great cardiac vein, Coronary Vein, Ventricle, Ostium, Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins — Research Paper | ScholarLens