2010Periodica Polytechnica Civil EngineeringOpen access

Temperature dependent load bearing capacity of laminated glass panes

Kinga Pankhardt, György L. Balázs

Open full text 15 citations

Abstract

An experimental programme with numerous single and laminated glass specimens was carried out to study the temperature dependent behaviour of laminated glasses. The difference of load bearing capacities between the laminate manufactured from ordinary float (laminated glass) or tempered glass layers (safety laminated glass) were also studied in four-point bending. When glass laminate fractures, the interlayer can keep the fragments in place. Different types of interlayer materials, both resin and foil (type EVA) were studied in safety and non safety laminated glass specimens. Glasses are used not only in the interior but also in exterior places. Therefore, the effect of temperature of -20o C, +23\r C and +60o C were investigated on bending characteristics of glasses. The main influencing factors on the load bearing capacity and bending characteristics of the glass specimens were investigated e.g. tempering, laminating and temperature.

Open-access reader

About this research paper

What this paper is about

An experimental programme with numerous single and laminated glass specimens was carried out to study the temperature dependent behaviour of laminated glasses. The difference of load bearing capacities between the laminate manufactured from ordinary float (laminated glass) or tempered glass layers (safety laminated glass) were also studied in four-point bending. When glass laminate fractures, the interlayer can keep the fragments in place. Different types of interlayer materials, both resin and foil (type EVA) were studied in safety and non safety laminated glass specimens. Glasses are used not only in the interior but also in exterior places. Therefore, the effect of temperature of -20o C, +23\r C and +60o C were investigated on bending characteristics of glasses. The main influencing factors on the load bearing capacity and bending characteristics of the glass specimens were investigated e.g. tempering, laminating and temperature.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An experimental programme with numerous single and laminated glass specimens was carried out to study the temperature dependent behaviour of laminated glasses. The difference of load bearing capacities between the laminate manufactured from ordinary float (laminated glass) or tempered glass layers (safety laminated glass) were also studied in four-point bending. When glass laminate fractures, the interlayer can keep the fragments in place. Different types of interlayer materials, both resin and foil (type EVA) were studied in safety and non safety laminated glass specimens. Glasses are used not only in the interior but also in exterior places. Therefore, the effect of temperature of -20o C, +23\r C and +60o C were investigated on bending characteristics of glasses. The main influencing factors on the load bearing capacity and bending characteristics of the glass specimens were investigated e.g. tempering, laminating and temperature.

Key concepts: Laminated glass, Toughened glass, Materials science, Composite material, Float glass, Load bearing, Bending, FOIL method

Related papers

Back to paper searchBrowse research topicsOriginal source
Temperature dependent load bearing capacity of laminated glass panes — Research Paper | ScholarLens