1983Journal of Engineering for PowerRequires access

Twenty-Five Years of Operating Experience With the Coal-Fired, Closed-Cycle Gas Turbine Cogeneration Plant at Coburg

Κ. Bammert

Open publisher page 10 citations

Abstract

The only commercially running closed-cycle gas turbine in the world delivering electricity as well as heat to a public utility and a heating network, is the heat and power station in Coburg, West Germany. The plant is fired exclusively with pulverized coal and uses air as the working medium. It has a maximum continuous electric power output of 6.6 MW into the grid and up to 16 MW of direct heating capacity into the town’s heating network. The plant has accumulated 150,000 operating hours to date (approximately 7000 hrs per year); it is scheduled to remain in service during the following years due to its excellent performance. Since relatively little has been published about the plant in the technical literature, a report about its design and operating experience is presented here.

About this research paper

What this paper is about

The only commercially running closed-cycle gas turbine in the world delivering electricity as well as heat to a public utility and a heating network, is the heat and power station in Coburg, West Germany. The plant is fired exclusively with pulverized coal and uses air as the working medium. It has a maximum continuous electric power output of 6.6 MW into the grid and up to 16 MW of direct heating capacity into the town’s heating network. The plant has accumulated 150,000 operating hours to date (approximately 7000 hrs per year); it is scheduled to remain in service during the following years due to its excellent performance. Since relatively little has been published about the plant in the technical literature, a report about its design and operating experience is presented here.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The only commercially running closed-cycle gas turbine in the world delivering electricity as well as heat to a public utility and a heating network, is the heat and power station in Coburg, West Germany. The plant is fired exclusively with pulverized coal and uses air as the working medium. It has a maximum continuous electric power output of 6.6 MW into the grid and up to 16 MW of direct heating capacity into the town’s heating network. The plant has accumulated 150,000 operating hours to date (approximately 7000 hrs per year); it is scheduled to remain in service during the following years due to its excellent performance. Since relatively little has been published about the plant in the technical literature, a report about its design and operating experience is presented here.

Key concepts: Cogeneration, Combined cycle, Coal, Power station, Gas turbines, Turbine, Waste management, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Twenty-Five Years of Operating Experience With the Coal-Fired, Closed-Cycle Gas Turbine Cogeneration Plant at Coburg — Research Paper | ScholarLens