Total lung capacity measured by body plethysmography and by the helium dilution method. A comparative study in different patient groups

L. G. Andersson, Ivar Ringqvist, Adrian M. Walker

Open publisher page 16 citations

Abstract

The helium dilution method is known to underestimate the total lung capacity (TLC) in patients with poorly or non-ventilated areas in the lungs. The standard plethysmographic method has been reported to overestimate TLC in patients with severe airway obstruction. To determine the magnitude of the difference between the two methods, a comparison was made in different patient groups. In a group of patients with normal lung function tests (n = 20) there was a small but significant average difference in TLC between plethysmography and the helium dilution method, the larger values being obtained with the latter. In patient groups with moderately obstructed airways (n = 23), severely obstructed airways (n = 20), or emphysema (n = 19), there were no significant average differences, although in two patients in the emphysema group the plethysmographic values were considerably larger than those obtained by helium dilution. We conclude that the gas dilution methods and plethysmography with a pressure-compensated volume displacement plethysmograph gave estimates of TLC which agreed even in patients with airway obstruction or emphysema, except in patients with very severe lung disease.

About this research paper

What this paper is about

The helium dilution method is known to underestimate the total lung capacity (TLC) in patients with poorly or non-ventilated areas in the lungs. The standard plethysmographic method has been reported to overestimate TLC in patients with severe airway obstruction. To determine the magnitude of the difference between the two methods, a comparison was made in different patient groups. In a group of patients with normal lung function tests (n = 20) there was a small but significant average difference in TLC between plethysmography and the helium dilution method, the larger values being obtained with the latter. In patient groups with moderately obstructed airways (n = 23), severely obstructed airways (n = 20), or emphysema (n = 19), there were no significant average differences, although in two patients in the emphysema group the plethysmographic values were considerably larger than those obtained by helium dilution. We conclude that the gas dilution methods and plethysmography with a pressure-compensated volume displacement plethysmograph gave estimates of TLC which agreed even in patients with airway obstruction or emphysema, except in patients with very severe lung disease.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The helium dilution method is known to underestimate the total lung capacity (TLC) in patients with poorly or non-ventilated areas in the lungs. The standard plethysmographic method has been reported to overestimate TLC in patients with severe airway obstruction. To determine the magnitude of the difference between the two methods, a comparison was made in different patient groups. In a group of patients with normal lung function tests (n = 20) there was a small but significant average difference in TLC between plethysmography and the helium dilution method, the larger values being obtained with the latter. In patient groups with moderately obstructed airways (n = 23), severely obstructed airways (n = 20), or emphysema (n = 19), there were no significant average differences, although in two patients in the emphysema group the plethysmographic values were considerably larger than those obtained by helium dilution. We conclude that the gas dilution methods and plethysmography with a pressure-compensated volume displacement plethysmograph gave estimates of TLC which agreed even in patients with airway obstruction or emphysema, except in patients with very severe lung disease.

Key concepts: Plethysmograph, Lung volumes, Lung, Medicine, Dilution, Cardiology, Internal medicine, Physics