1992AnesthesiologyRequires access

Monitoring of Heparin-induced Anticoagulation with Kaolinactivated Clotting Time in Cardiac Surgical Patients Treated with Aprotinin

Jiansheng Wang, Chung-Yuan Lin, Wei‐Te Hung, Robert B. Karp

Open publisher page 98 citations

Abstract

High-dose aprotinin appears to enhance the anticoagulant effects of heparin, as documented by increases in the activated clotting times (ACTs) during cardiopulmonary bypass; hence, some authorities have advocated reducing the dose of heparin in patients treated with aprotinin. An in vitro study by our group suggested that the increase of the ACT in the presence of aprotinin and heparin may be due to the use of celite as surface activator. We compared celite and kaolin as surface activators for the measurement of the ACT in cardiac surgical patients treated with aprotinin and in patients given no aprotinin. This double-blind, randomized, placebo-controlled study included 30 patients, of whom 14 received aprotinin and 16 received a placebo. Before, during, and after cardiopulmonary bypass, the ACT was measured with two Hemochron 400 systems with 12 mg of either celite (C-ACT) or kaolin (K-ACT) used as surface activator and with one Hepcon HMS system (HR-ACT), which uses kaolin as activator. The latter also was used for measurement of the blood heparin concentration. The ACTs of blood without heparin did not differ between aprotinin and control patients. During anticoagulation with heparin and cardiopulmonary bypass, the average C-ACTs were 784 +/- 301 s (aprotinin) and 496 +/- 120 s (control) (P < .001); the K-ACTs were 502 +/- 131 s (aprotinin) and 458 +/- 101 s (control) (P > .05); the HR-ACTs were 406 +/- 87 s (aprotinin) and 423 +/- 82 s (control) (P > .05), which was consistently less than C-ACT and K-ACT.(ABSTRACT TRUNCATED AT 250 WORDS)

About this research paper

What this paper is about

High-dose aprotinin appears to enhance the anticoagulant effects of heparin, as documented by increases in the activated clotting times (ACTs) during cardiopulmonary bypass; hence, some authorities have advocated reducing the dose of heparin in patients treated with aprotinin. An in vitro study by our group suggested that the increase of the ACT in the presence of aprotinin and heparin may be due to the use of celite as surface activator. We compared celite and kaolin as surface activators for the measurement of the ACT in cardiac surgical patients treated with aprotinin and in patients given no aprotinin. This double-blind, randomized, placebo-controlled study included 30 patients, of whom 14 received aprotinin and 16 received a placebo. Before, during, and after cardiopulmonary bypass, the ACT was measured with two Hemochron 400 systems with 12 mg of either celite (C-ACT) or kaolin (K-ACT) used as surface activator and with one Hepcon HMS system (HR-ACT), which uses kaolin as activator. The latter also was used for measurement of the blood heparin concentration. The ACTs of blood without heparin did not differ between aprotinin and control patients. During anticoagulation with heparin and cardiopulmonary bypass, the average C-ACTs were 784 +/- 301 s (aprotinin) and 496 +/- 120 s (control) (P < .001); the K-ACTs were 502 +/- 131 s (aprotinin) and 458 +/- 101 s (control) (P > .05); the HR-ACTs were 406 +/- 87 s (aprotinin) and 423 +/- 82 s (control) (P > .05), which was consistently less than C-ACT and K-ACT.(ABSTRACT TRUNCATED AT 250 WORDS)

Why it matters

OpenAlex reports 98 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High-dose aprotinin appears to enhance the anticoagulant effects of heparin, as documented by increases in the activated clotting times (ACTs) during cardiopulmonary bypass; hence, some authorities have advocated reducing the dose of heparin in patients treated with aprotinin. An in vitro study by our group suggested that the increase of the ACT in the presence of aprotinin and heparin may be due to the use of celite as surface activator. We compared celite and kaolin as surface activators for the measurement of the ACT in cardiac surgical patients treated with aprotinin and in patients given no aprotinin. This double-blind, randomized, placebo-controlled study included 30 patients, of whom 14 received aprotinin and 16 received a placebo. Before, during, and after cardiopulmonary bypass, the ACT was measured with two Hemochron 400 systems with 12 mg of either celite (C-ACT) or kaolin (K-ACT) used as surface activator and with one Hepcon HMS system (HR-ACT), which uses kaolin as activator. The latter also was used for measurement of the blood heparin concentration. The ACTs of blood without heparin did not differ between aprotinin and control patients. During anticoagulation with heparin and cardiopulmonary bypass, the average C-ACTs were 784 +/- 301 s (aprotinin) and 496 +/- 120 s (control) (P < .001); the K-ACTs were 502 +/- 131 s (aprotinin) and 458 +/- 101 s (control) (P > .05); the HR-ACTs were 406 +/- 87 s (aprotinin) and 423 +/- 82 s (control) (P > .05), which was consistently less than C-ACT and K-ACT.(ABSTRACT TRUNCATED AT 250 WORDS)

Key concepts: Aprotinin, Activated clotting time, Heparin, Medicine, Cardiopulmonary bypass, Anesthesia, Placebo, Anticoagulant

Related papers

Back to paper searchBrowse research topicsOriginal source
Monitoring of Heparin-induced Anticoagulation with Kaolinactivated Clotting Time in Cardiac Surgical Patients Treated with Aprotinin — Research Paper | ScholarLens