1995Journal of Liquid ChromatographyRequires access

Urinary Protein and Albumin Determinations by High-Performance Gel-Permeation Chromatography

Kou Hayakawa, Elena A. Terentyeva, Ayako Tanae, Claudio De Felice, Toshiaki Tanaka, Kazuyuki Yoshikawa, Kunio YAMAUCHI

Open publisher page 5 citations

Abstract

Sensitive high-performance gel-permeation chromatographic protein assay method was developed by using non-ionic detergent of Brij-58 which was UV transparent as compared to Nonidet P-40. A column (70 × 8.0 mm I.D.) packed with Develosil 100 Diol-5 (pore size 10 nm) was used for the protein determination. A commercially available column (300 × 8.0 mm I.D.) packed with Develosil 300 Diol-5 (pore size 30 nm) was used for the urinary albumin determination. Eluent used was a 0.1 M sodium phosphate buffer (pH 5.6) containing 0.3 M sodium chloride, 1% (v/v) Brij-58, 50% (v/v) glycerol. Flow-rates for protein assay and albumin assay were 1.0 and 0.5 ml/min, repectively. Proteins were eluted at the position of the exclusion limit in the case of protein assay (100 Diol-5). Albumin was eluted from 300 Diol-5 column as a symmetric peak. Bovine serum albumin (BSA) was used as an external standard for both protein and albumin assays. Analysis times were within four min for protein assay, and 32 min for albumin assay, respectively. Improved sensitive measurement of BSA at 5–20 ng level was achieved as compared to Nonidet P-40 by use of UV 210 nm. This method was successfully applied for various urine samples, such as healthy random urine of before and after sports, and the 24-h urines from insulin-dependent diabetes mellitus (IDDM) patients. Comparisons with clinical urinary protein and albumin tests were performed using IDDM urine. Three cases out of four tests for sports showed increased protein and albumin content after physical exercise. Thus, this HPLC method was proven to be applicable to the protein and albumin measurements in human urine.

About this research paper

What this paper is about

Sensitive high-performance gel-permeation chromatographic protein assay method was developed by using non-ionic detergent of Brij-58 which was UV transparent as compared to Nonidet P-40. A column (70 × 8.0 mm I.D.) packed with Develosil 100 Diol-5 (pore size 10 nm) was used for the protein determination. A commercially available column (300 × 8.0 mm I.D.) packed with Develosil 300 Diol-5 (pore size 30 nm) was used for the urinary albumin determination. Eluent used was a 0.1 M sodium phosphate buffer (pH 5.6) containing 0.3 M sodium chloride, 1% (v/v) Brij-58, 50% (v/v) glycerol. Flow-rates for protein assay and albumin assay were 1.0 and 0.5 ml/min, repectively. Proteins were eluted at the position of the exclusion limit in the case of protein assay (100 Diol-5). Albumin was eluted from 300 Diol-5 column as a symmetric peak. Bovine serum albumin (BSA) was used as an external standard for both protein and albumin assays. Analysis times were within four min for protein assay, and 32 min for albumin assay, respectively. Improved sensitive measurement of BSA at 5–20 ng level was achieved as compared to Nonidet P-40 by use of UV 210 nm. This method was successfully applied for various urine samples, such as healthy random urine of before and after sports, and the 24-h urines from insulin-dependent diabetes mellitus (IDDM) patients. Comparisons with clinical urinary protein and albumin tests were performed using IDDM urine. Three cases out of four tests for sports showed increased protein and albumin content after physical exercise. Thus, this HPLC method was proven to be applicable to the protein and albumin measurements in human urine.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sensitive high-performance gel-permeation chromatographic protein assay method was developed by using non-ionic detergent of Brij-58 which was UV transparent as compared to Nonidet P-40. A column (70 × 8.0 mm I.D.) packed with Develosil 100 Diol-5 (pore size 10 nm) was used for the protein determination. A commercially available column (300 × 8.0 mm I.D.) packed with Develosil 300 Diol-5 (pore size 30 nm) was used for the urinary albumin determination. Eluent used was a 0.1 M sodium phosphate buffer (pH 5.6) containing 0.3 M sodium chloride, 1% (v/v) Brij-58, 50% (v/v) glycerol. Flow-rates for protein assay and albumin assay were 1.0 and 0.5 ml/min, repectively. Proteins were eluted at the position of the exclusion limit in the case of protein assay (100 Diol-5). Albumin was eluted from 300 Diol-5 column as a symmetric peak. Bovine serum albumin (BSA) was used as an external standard for both protein and albumin assays. Analysis times were within four min for protein assay, and 32 min for albumin assay, respectively. Improved sensitive measurement of BSA at 5–20 ng level was achieved as compared to Nonidet P-40 by use of UV 210 nm. This method was successfully applied for various urine samples, such as healthy random urine of before and after sports, and the 24-h urines from insulin-dependent diabetes mellitus (IDDM) patients. Comparisons with clinical urinary protein and albumin tests were performed using IDDM urine. Three cases out of four tests for sports showed increased protein and albumin content after physical exercise. Thus, this HPLC method was proven to be applicable to the protein and albumin measurements in human urine.

Key concepts: Chromatography, Chemistry, Albumin, Bovine serum albumin, Elution, Gel permeation chromatography, Serum albumin, Sodium

Related papers

Back to paper searchBrowse research topicsOriginal source
Urinary Protein and Albumin Determinations by High-Performance Gel-Permeation Chromatography — Research Paper | ScholarLens