1979Journal of Dental ResearchRequires access

The Quantitative Measurement of the Opacity of Aesthetic Dental Filling Materials

Stephen Crisp, G. Abel, Alan D. Wilson

Open publisher page 34 citations

Abstract

A method is described for measuring the opacity of anesthetic dental filling materials using a goniophotometer. Procedures are given for converting measured opacity values to those referred to a 70% reflectance background (C0.7 values) as required by existing specifications. The conversion is involved, and, since most available white surfaces have reflectance of about 80%, it is recommended that in future specifications opacity be recorded as C0.8 values. Opacity values for 28 materials are reported. It was found that the opacity of dental cement decreases for several days following preparation and that powder/liquid ratio has little effect, while pigmentation has a marked effect on opacity.

About this research paper

What this paper is about

A method is described for measuring the opacity of anesthetic dental filling materials using a goniophotometer. Procedures are given for converting measured opacity values to those referred to a 70% reflectance background (C0.7 values) as required by existing specifications. The conversion is involved, and, since most available white surfaces have reflectance of about 80%, it is recommended that in future specifications opacity be recorded as C0.8 values. Opacity values for 28 materials are reported. It was found that the opacity of dental cement decreases for several days following preparation and that powder/liquid ratio has little effect, while pigmentation has a marked effect on opacity.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method is described for measuring the opacity of anesthetic dental filling materials using a goniophotometer. Procedures are given for converting measured opacity values to those referred to a 70% reflectance background (C0.7 values) as required by existing specifications. The conversion is involved, and, since most available white surfaces have reflectance of about 80%, it is recommended that in future specifications opacity be recorded as C0.8 values. Opacity values for 28 materials are reported. It was found that the opacity of dental cement decreases for several days following preparation and that powder/liquid ratio has little effect, while pigmentation has a marked effect on opacity.

Key concepts: Opacity, Reflectivity, Dentistry, Medicine, Materials science, Optics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
The Quantitative Measurement of the Opacity of Aesthetic Dental Filling Materials — Research Paper | ScholarLens