Comparison of β-Thromboglobulin, Flow Cytometry, and Platelet Aggregometry to Study Platelet Activation
Axel Matzdorff, B. Kemkes‐Matthes, R. Voss, H. Pralle
Abstract
Axel Matzdorff, B. Kemkes‐Matthes, R. Voss, H. Pralle
Abstract
This study compares granule membrane protein (GMP)-140 expression measured by flow cytometry, release of beta-thromboglobulin (beta-TG), and platelet aggregometry as markers of platelet activation in vitro. Whole blood was activated with different concentrations of thrombin. There was a significant increase in beta-TG plasma levels after stimulation with 0.01 and 0.04 U thrombin/ml. There was also an increase in GMP-140 expression, but interindividual variability was high. Aggregometry of platelet-rich plasma did not detect platelet activation and formation of platelet aggregates with 0.05 and 0.1 U thrombin/ml, while flow cytometry showed an early and significant increase of GMP-140 expression with these doses. Beta-TG release is a more sensitive marker of platelet activation than GMP-140 while flow cytometry is easier to perform and less susceptible to artifacts.
OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study compares granule membrane protein (GMP)-140 expression measured by flow cytometry, release of beta-thromboglobulin (beta-TG), and platelet aggregometry as markers of platelet activation in vitro. Whole blood was activated with different concentrations of thrombin. There was a significant increase in beta-TG plasma levels after stimulation with 0.01 and 0.04 U thrombin/ml. There was also an increase in GMP-140 expression, but interindividual variability was high. Aggregometry of platelet-rich plasma did not detect platelet activation and formation of platelet aggregates with 0.05 and 0.1 U thrombin/ml, while flow cytometry showed an early and significant increase of GMP-140 expression with these doses. Beta-TG release is a more sensitive marker of platelet activation than GMP-140 while flow cytometry is easier to perform and less susceptible to artifacts.
Key concepts: Platelet, Flow cytometry, Platelet activation, Platelet factor 4, Chemistry, Medicine, Immunology