2011Scientia IranicaOpen access

Determination of silver(I) by flame atomic absorption spectrometry after separation/preconcentration using modified magnetite nanoparticles

Mohammad Ali Karimi, Sayed Zia Mohammadi, Alireza Mohadesi, Abdolhamid Hatefi‐Mehrjardi, Mohammad Mazloum‐Ardakani, L. Sotudehnia Korani, A. Kabir

Open full text 65 citations

Abstract

Abstract A new, simple, fast and reliable method has been developed for the separation/preconcentration of trace amounts of silver ions using 2-mercaptobenzothiazole/sodium dodecyl sulfate immobilized on alumina-coated magnetite nanoparticles (MBT/SDS-ACMNPs) and their determination by flame atomic absorption spectrometry (FAAS). Optimal experimental conditions, including pH, sample volume, eluent concentration and volume, and co-existing ions, have been studied and established. Under optimal experimental conditions, the enrichment factor, detection limit, linear range and relative standard deviation (RSD) of Ag(I) ions were 250 (for 500 mL of sample solution), 0.56 ng mL −1 , 2.0–100.0 ng mL −1 and 3.1% (for 5.0 μg mL −1 , n = 10 ), respectively. The presented procedure was successfully applied for determination of silver content in the different samples of water.

About this research paper

What this paper is about

Abstract A new, simple, fast and reliable method has been developed for the separation/preconcentration of trace amounts of silver ions using 2-mercaptobenzothiazole/sodium dodecyl sulfate immobilized on alumina-coated magnetite nanoparticles (MBT/SDS-ACMNPs) and their determination by flame atomic absorption spectrometry (FAAS). Optimal experimental conditions, including pH, sample volume, eluent concentration and volume, and co-existing ions, have been studied and established. Under optimal experimental conditions, the enrichment factor, detection limit, linear range and relative standard deviation (RSD) of Ag(I) ions were 250 (for 500 mL of sample solution), 0.56 ng mL −1 , 2.0–100.0 ng mL −1 and 3.1% (for 5.0 μg mL −1 , n = 10 ), respectively. The presented procedure was successfully applied for determination of silver content in the different samples of water.

Why it matters

OpenAlex reports 65 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A new, simple, fast and reliable method has been developed for the separation/preconcentration of trace amounts of silver ions using 2-mercaptobenzothiazole/sodium dodecyl sulfate immobilized on alumina-coated magnetite nanoparticles (MBT/SDS-ACMNPs) and their determination by flame atomic absorption spectrometry (FAAS). Optimal experimental conditions, including pH, sample volume, eluent concentration and volume, and co-existing ions, have been studied and established. Under optimal experimental conditions, the enrichment factor, detection limit, linear range and relative standard deviation (RSD) of Ag(I) ions were 250 (for 500 mL of sample solution), 0.56 ng mL −1 , 2.0–100.0 ng mL −1 and 3.1% (for 5.0 μg mL −1 , n = 10 ), respectively. The presented procedure was successfully applied for determination of silver content in the different samples of water.

Key concepts: Magnetite Nanoparticles, Magnetite, Atomic absorption spectroscopy, Materials science, Nanoparticle, Analytical Chemistry (journal), Mass spectrometry, Absorption (acoustics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of silver(I) by flame atomic absorption spectrometry after separation/preconcentration using modified magnetite nanoparticles — Research Paper | ScholarLens