1991IEEE Transactions on Power DeliveryRequires access

A personal computer based system for the laboratory evaluation of high performance power system protection relays

M.A. Redfern, R.K. Aggarwal, Ahmad Husseini

Open publisher page 26 citations

Abstract

The power system simulation system described provides a relay under evaluation with current and voltage input similar to that encountered under service and fault conditions. Using digital transient simulation programs to model power system behaviour, the facility provides an effective bandwidth of from DC to 4 kHz for both the current and voltage relay input. The relay's output is automatically monitored during the test, enabling a detailed report of its response to be produced. The application of the system is illustrated by the evaluation of a new EHV teed feeder relaying system.>

About this research paper

What this paper is about

The power system simulation system described provides a relay under evaluation with current and voltage input similar to that encountered under service and fault conditions. Using digital transient simulation programs to model power system behaviour, the facility provides an effective bandwidth of from DC to 4 kHz for both the current and voltage relay input. The relay's output is automatically monitored during the test, enabling a detailed report of its response to be produced. The application of the system is illustrated by the evaluation of a new EHV teed feeder relaying system.>

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The power system simulation system described provides a relay under evaluation with current and voltage input similar to that encountered under service and fault conditions. Using digital transient simulation programs to model power system behaviour, the facility provides an effective bandwidth of from DC to 4 kHz for both the current and voltage relay input. The relay's output is automatically monitored during the test, enabling a detailed report of its response to be produced. The application of the system is illustrated by the evaluation of a new EHV teed feeder relaying system.>

Key concepts: Relay, Protective relay, Digital protective relay, Electric power system, Transient (computer programming), Electrical engineering, Power-system protection, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A personal computer based system for the laboratory evaluation of high performance power system protection relays — Research Paper | ScholarLens