2005Journal of Bone and Joint SurgeryRequires access

Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A Prospective, Randomized Study

Young‐Hoo Kim

Open publisher page 262 citations

Abstract

BACKGROUND: The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty. METHODS: Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery. RESULTS: The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 105 degrees to 150 degrees ) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees ) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis. CONCLUSIONS: After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.

About this research paper

What this paper is about

BACKGROUND: The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty. METHODS: Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery. RESULTS: The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 105 degrees to 150 degrees ) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees ) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis. CONCLUSIONS: After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.

Why it matters

OpenAlex reports 262 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty. METHODS: Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery. RESULTS: The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 105 degrees to 150 degrees ) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees ) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis. CONCLUSIONS: After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.

Key concepts: Medicine, Prosthesis, Range of motion, Surgery, Condyle, Radiography, Total knee arthroplasty, Knee flexion

Related papers

Back to paper searchBrowse research topicsOriginal source
Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A Prospective, Randomized Study — Research Paper | ScholarLens