2004•Journal of Agricultural and Food ChemistryRequires access

Are Molecular Weights of Proteins Determined by Superose 12 Column Chromatography Correct?

Shih-Chieh Lee, John R. Whitaker

Open publisher page 11 citations

Abstract

Our research on several proteins indicates that accurate molecular weights cannot be determined by Superose 12 column chromatography. In support of this statement, we present data on molecular weights of purified red kidney bean alpha-amylase inhibitor (RKB alphaAI) and white kidney bean alpha-amylase inhibitor (WKB alphaAI) to document this problem. The molecular weight of purified RKB alphaAI determined by Sephadex G-100 gel filtration, polyacrylamide gel electrophoresis, Superose 12 gel filtration and cDNA were 49.0, 51.0, 22.9, and 49.805 kDa (not glycosylated), respectively. The molecular weights of WKB alphaAI by several methods were as follows: Sephadex G-100 gel filtration, 51.0 kDa; Superose 12 gel filtration in 0.2 M NaCl buffer, 23.1 kDa; polyacrylamide gel electrophoresis (PAGE), 51.0 kDa; sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), 45.0 kDa; multiangle laser light scattering (MALLS), 49.940 kDa; laser-assisted time-of-flight mass spectrometry (LATOFMS), 56.714 kDa; and cDNA sequence (with 12.2% carbohydrate), 55.9 kDa. The data indicate there is ionic interaction between proteins and the matrix of Superose 12 in low ionic strength buffers and hydrophobic interaction at higher ionic strength buffers. Researchers should be cautious when using Superose 12 columns for molecular weight determinations.

About this research paper

What this paper is about

Our research on several proteins indicates that accurate molecular weights cannot be determined by Superose 12 column chromatography. In support of this statement, we present data on molecular weights of purified red kidney bean alpha-amylase inhibitor (RKB alphaAI) and white kidney bean alpha-amylase inhibitor (WKB alphaAI) to document this problem. The molecular weight of purified RKB alphaAI determined by Sephadex G-100 gel filtration, polyacrylamide gel electrophoresis, Superose 12 gel filtration and cDNA were 49.0, 51.0, 22.9, and 49.805 kDa (not glycosylated), respectively. The molecular weights of WKB alphaAI by several methods were as follows: Sephadex G-100 gel filtration, 51.0 kDa; Superose 12 gel filtration in 0.2 M NaCl buffer, 23.1 kDa; polyacrylamide gel electrophoresis (PAGE), 51.0 kDa; sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), 45.0 kDa; multiangle laser light scattering (MALLS), 49.940 kDa; laser-assisted time-of-flight mass spectrometry (LATOFMS), 56.714 kDa; and cDNA sequence (with 12.2% carbohydrate), 55.9 kDa. The data indicate there is ionic interaction between proteins and the matrix of Superose 12 in low ionic strength buffers and hydrophobic interaction at higher ionic strength buffers. Researchers should be cautious when using Superose 12 columns for molecular weight determinations.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Our research on several proteins indicates that accurate molecular weights cannot be determined by Superose 12 column chromatography. In support of this statement, we present data on molecular weights of purified red kidney bean alpha-amylase inhibitor (RKB alphaAI) and white kidney bean alpha-amylase inhibitor (WKB alphaAI) to document this problem. The molecular weight of purified RKB alphaAI determined by Sephadex G-100 gel filtration, polyacrylamide gel electrophoresis, Superose 12 gel filtration and cDNA were 49.0, 51.0, 22.9, and 49.805 kDa (not glycosylated), respectively. The molecular weights of WKB alphaAI by several methods were as follows: Sephadex G-100 gel filtration, 51.0 kDa; Superose 12 gel filtration in 0.2 M NaCl buffer, 23.1 kDa; polyacrylamide gel electrophoresis (PAGE), 51.0 kDa; sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), 45.0 kDa; multiangle laser light scattering (MALLS), 49.940 kDa; laser-assisted time-of-flight mass spectrometry (LATOFMS), 56.714 kDa; and cDNA sequence (with 12.2% carbohydrate), 55.9 kDa. The data indicate there is ionic interaction between proteins and the matrix of Superose 12 in low ionic strength buffers and hydrophobic interaction at higher ionic strength buffers. Researchers should be cautious when using Superose 12 columns for molecular weight determinations.

Key concepts: Size-exclusion chromatography, Chromatography, Sephadex, Chemistry, Polyacrylamide gel electrophoresis, Molecular mass, Gel electrophoresis, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Are Molecular Weights of Proteins Determined by Superose 12 Column Chromatography Correct? — Research Paper | ScholarLens