1990•Circulation ResearchOpen access

Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy.

Janice L. Jones, John F. Swartz, R. E. Jones, Ross D. Fletcher

Open full text 69 citations

Abstract

Biphasic waveforms reduce defibrillation threshold compared with corresponding monophasic waveforms. However, effects of fibrillation duration on relative efficacy of monophasic and biphasic waveforms are unknown. This study used a newly developed defibrillation model, the isolated right- and left-sided working rabbit heart, with epicardial defibrillation electrodes, to compare threshold for a monophasic waveform (5 msec rectangular) and an asymmetrical biphasic waveform (5 msec each pulse, V2 = 50% V1). Mean voltage defibrillation threshold (V50) was determined from sigmoidal probability of successful defibrillation versus shock intensity curves after 5, 15, and 30 seconds of fibrillation in a paired study with 10 hearts. Results showed that biphasic waveforms had significantly lower voltage and energy thresholds at all fibrillation durations and that their relative efficacy improved with increasing fibrillation duration. Biphasic voltage threshold was 38.2 +/- 2.2, 44.7 +/- 4.8, and 46.6 +/- 3.2 V after 5, 15, and 30 seconds of fibrillation compared with monophasic thresholds of 51.7 +/- 4.4 (p less than 0.002), 63.0 +/- 7.6 (p less than 0.05), and 72.1 +/- 3.9 V (p less than 0.005). Biphasic waveform energy threshold was 0.67 that for the monophasic waveform after 5 seconds of fibrillation (0.12 +/- 0.01 versus 0.18 +/- 0.03 J, p less than 0.05). The ratio between biphasic waveform threshold and monophasic waveform threshold (B/M) decreased to 0.62 at 15 seconds. At 30 seconds, B/M was 0.52 (0.17 +/- 0.02 versus 0.33 +/- 0.04 J, p less than 0.02). This study also showed that biphasic waveform threshold was a nonlinear function of monophasic waveform threshold so that improved biphasic defibrillator waveform efficacy was greatest for hearts having higher monophasic thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Open-access reader

About this research paper

What this paper is about

Biphasic waveforms reduce defibrillation threshold compared with corresponding monophasic waveforms. However, effects of fibrillation duration on relative efficacy of monophasic and biphasic waveforms are unknown. This study used a newly developed defibrillation model, the isolated right- and left-sided working rabbit heart, with epicardial defibrillation electrodes, to compare threshold for a monophasic waveform (5 msec rectangular) and an asymmetrical biphasic waveform (5 msec each pulse, V2 = 50% V1). Mean voltage defibrillation threshold (V50) was determined from sigmoidal probability of successful defibrillation versus shock intensity curves after 5, 15, and 30 seconds of fibrillation in a paired study with 10 hearts. Results showed that biphasic waveforms had significantly lower voltage and energy thresholds at all fibrillation durations and that their relative efficacy improved with increasing fibrillation duration. Biphasic voltage threshold was 38.2 +/- 2.2, 44.7 +/- 4.8, and 46.6 +/- 3.2 V after 5, 15, and 30 seconds of fibrillation compared with monophasic thresholds of 51.7 +/- 4.4 (p less than 0.002), 63.0 +/- 7.6 (p less than 0.05), and 72.1 +/- 3.9 V (p less than 0.005). Biphasic waveform energy threshold was 0.67 that for the monophasic waveform after 5 seconds of fibrillation (0.12 +/- 0.01 versus 0.18 +/- 0.03 J, p less than 0.05). The ratio between biphasic waveform threshold and monophasic waveform threshold (B/M) decreased to 0.62 at 15 seconds. At 30 seconds, B/M was 0.52 (0.17 +/- 0.02 versus 0.33 +/- 0.04 J, p less than 0.02). This study also showed that biphasic waveform threshold was a nonlinear function of monophasic waveform threshold so that improved biphasic defibrillator waveform efficacy was greatest for hearts having higher monophasic thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Why it matters

OpenAlex reports 69 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Biphasic waveforms reduce defibrillation threshold compared with corresponding monophasic waveforms. However, effects of fibrillation duration on relative efficacy of monophasic and biphasic waveforms are unknown. This study used a newly developed defibrillation model, the isolated right- and left-sided working rabbit heart, with epicardial defibrillation electrodes, to compare threshold for a monophasic waveform (5 msec rectangular) and an asymmetrical biphasic waveform (5 msec each pulse, V2 = 50% V1). Mean voltage defibrillation threshold (V50) was determined from sigmoidal probability of successful defibrillation versus shock intensity curves after 5, 15, and 30 seconds of fibrillation in a paired study with 10 hearts. Results showed that biphasic waveforms had significantly lower voltage and energy thresholds at all fibrillation durations and that their relative efficacy improved with increasing fibrillation duration. Biphasic voltage threshold was 38.2 +/- 2.2, 44.7 +/- 4.8, and 46.6 +/- 3.2 V after 5, 15, and 30 seconds of fibrillation compared with monophasic thresholds of 51.7 +/- 4.4 (p less than 0.002), 63.0 +/- 7.6 (p less than 0.05), and 72.1 +/- 3.9 V (p less than 0.005). Biphasic waveform energy threshold was 0.67 that for the monophasic waveform after 5 seconds of fibrillation (0.12 +/- 0.01 versus 0.18 +/- 0.03 J, p less than 0.05). The ratio between biphasic waveform threshold and monophasic waveform threshold (B/M) decreased to 0.62 at 15 seconds. At 30 seconds, B/M was 0.52 (0.17 +/- 0.02 versus 0.33 +/- 0.04 J, p less than 0.02). This study also showed that biphasic waveform threshold was a nonlinear function of monophasic waveform threshold so that improved biphasic defibrillator waveform efficacy was greatest for hearts having higher monophasic thresholds.(ABSTRACT TRUNCATED AT 250 WORDS)

Key concepts: Defibrillation, Defibrillation threshold, Waveform, Ventricular fibrillation, Cardiology, Fibrillation, Internal medicine, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy. — Research Paper | ScholarLens