2014Peritoneal Dialysis InternationalOpen access

Measuring Peritoneal Absorption with the Prolonged Peritoneal Equilibration Test from 4 to 8 Hours Using Various Glucose Concentrations

Josep Teixidó–Planas, María Isabel Troya, Guillermo Pedreira‐Robles, Milagros Del-Rio–Lafuente, Ramon Romero–Gonzalez, Josep Bonet–Sol

Open full text 11 citations

Abstract

BACKGROUND: Peritoneal fluid flows such as small-pore ultrafiltration and free water transport can now be calculated by means of the modified peritoneal equilibration test (PET). To calculate peritoneal fluid absorption, volume markers have been used, but that method is not easily applicable in clinical practice. Alternatively, absorption can be estimated using the personal dialysis capacity test. However, a method of measuring overall peritoneal absorption together with the PET is lacking. The aim of the present study was to assess whether overall peritoneal absorption was different when measured from the 4th to 8th hour in a prolonged PET using three different glucose solutions. METHODS: The study enrolled 32 stable peritoneal dialysis (PD) patients from a tertiary university hospital, who underwent three 8-hour prolonged PETs with 1.36%, 2.27%, and 3.86% glucose solution. The PETs were performed in random order over a period of less than 1 month. During the prolonged PET, the peritoneal volume was emptied and reinfused at 60 and 240 minutes and drained at 480 minutes. Peritoneal absorption was calculated as the volume difference between the 4th and the 8th hour. RESULTS: The dialysate-to-plasma ratio (D/P) of urea, the D/P creatinine, and the mass transfer area coefficient (MTC) of creatinine at 240 minutes were not significantly different with the three glucose solutions. The end-to-initial (D/D0) glucose, MTC urea, and MTC glucose were significantly different. All water transport parameters were significantly different, except for the 4- to 8-hour absorption volumes and rates. The peritoneal absorption rates were, for 1.36% solution, 1.03 ± 0.58 mL/min [95% confidence interval (CI): 0.83 to 1.24 mL/min]; for 2.27% solution, 0.86 ± 0.71 mL/min (95% CI: 0.61 to 1.11 mL/min); and for 3.86% solution, 1.05 ± 0.78 mL/min (95% CI: 0.77 to 1.33 mL/min). Peritoneal absorption volumes and rates from the 4th to the 8th hour showed good correlations for the various solutions. CONCLUSIONS: Using any glucose solution, the prolonged PET with voiding and reinfusion at the 4th hour could be a practical method for calculating overall peritoneal absorption from the 4th to the 8th hour in PD patients.

About this research paper

What this paper is about

BACKGROUND: Peritoneal fluid flows such as small-pore ultrafiltration and free water transport can now be calculated by means of the modified peritoneal equilibration test (PET). To calculate peritoneal fluid absorption, volume markers have been used, but that method is not easily applicable in clinical practice. Alternatively, absorption can be estimated using the personal dialysis capacity test. However, a method of measuring overall peritoneal absorption together with the PET is lacking. The aim of the present study was to assess whether overall peritoneal absorption was different when measured from the 4th to 8th hour in a prolonged PET using three different glucose solutions. METHODS: The study enrolled 32 stable peritoneal dialysis (PD) patients from a tertiary university hospital, who underwent three 8-hour prolonged PETs with 1.36%, 2.27%, and 3.86% glucose solution. The PETs were performed in random order over a period of less than 1 month. During the prolonged PET, the peritoneal volume was emptied and reinfused at 60 and 240 minutes and drained at 480 minutes. Peritoneal absorption was calculated as the volume difference between the 4th and the 8th hour. RESULTS: The dialysate-to-plasma ratio (D/P) of urea, the D/P creatinine, and the mass transfer area coefficient (MTC) of creatinine at 240 minutes were not significantly different with the three glucose solutions. The end-to-initial (D/D0) glucose, MTC urea, and MTC glucose were significantly different. All water transport parameters were significantly different, except for the 4- to 8-hour absorption volumes and rates. The peritoneal absorption rates were, for 1.36% solution, 1.03 ± 0.58 mL/min [95% confidence interval (CI): 0.83 to 1.24 mL/min]; for 2.27% solution, 0.86 ± 0.71 mL/min (95% CI: 0.61 to 1.11 mL/min); and for 3.86% solution, 1.05 ± 0.78 mL/min (95% CI: 0.77 to 1.33 mL/min). Peritoneal absorption volumes and rates from the 4th to the 8th hour showed good correlations for the various solutions. CONCLUSIONS: Using any glucose solution, the prolonged PET with voiding and reinfusion at the 4th hour could be a practical method for calculating overall peritoneal absorption from the 4th to the 8th hour in PD patients.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Peritoneal fluid flows such as small-pore ultrafiltration and free water transport can now be calculated by means of the modified peritoneal equilibration test (PET). To calculate peritoneal fluid absorption, volume markers have been used, but that method is not easily applicable in clinical practice. Alternatively, absorption can be estimated using the personal dialysis capacity test. However, a method of measuring overall peritoneal absorption together with the PET is lacking. The aim of the present study was to assess whether overall peritoneal absorption was different when measured from the 4th to 8th hour in a prolonged PET using three different glucose solutions. METHODS: The study enrolled 32 stable peritoneal dialysis (PD) patients from a tertiary university hospital, who underwent three 8-hour prolonged PETs with 1.36%, 2.27%, and 3.86% glucose solution. The PETs were performed in random order over a period of less than 1 month. During the prolonged PET, the peritoneal volume was emptied and reinfused at 60 and 240 minutes and drained at 480 minutes. Peritoneal absorption was calculated as the volume difference between the 4th and the 8th hour. RESULTS: The dialysate-to-plasma ratio (D/P) of urea, the D/P creatinine, and the mass transfer area coefficient (MTC) of creatinine at 240 minutes were not significantly different with the three glucose solutions. The end-to-initial (D/D0) glucose, MTC urea, and MTC glucose were significantly different. All water transport parameters were significantly different, except for the 4- to 8-hour absorption volumes and rates. The peritoneal absorption rates were, for 1.36% solution, 1.03 ± 0.58 mL/min [95% confidence interval (CI): 0.83 to 1.24 mL/min]; for 2.27% solution, 0.86 ± 0.71 mL/min (95% CI: 0.61 to 1.11 mL/min); and for 3.86% solution, 1.05 ± 0.78 mL/min (95% CI: 0.77 to 1.33 mL/min). Peritoneal absorption volumes and rates from the 4th to the 8th hour showed good correlations for the various solutions. CONCLUSIONS: Using any glucose solution, the prolonged PET with voiding and reinfusion at the 4th hour could be a practical method for calculating overall peritoneal absorption from the 4th to the 8th hour in PD patients.

Key concepts: Peritoneal dialysis, Peritoneal equilibration test, Medicine, Urology, Peritoneal fluid, Creatinine, Absorption (acoustics), Urea

Related papers

Back to paper searchBrowse research topicsOriginal source
Measuring Peritoneal Absorption with the Prolonged Peritoneal Equilibration Test from 4 to 8 Hours Using Various Glucose Concentrations — Research Paper | ScholarLens