Evaluation of a hepatocyte‐entrapment hollow fiber bioreactor: A potential bioartificial liver
Scott L. Nyberg, Russel A. Shatford, Madhusudan V. Peshwa, James G. White, Frank B. Cerra, Wei‐Shou Hu
Abstract
Scott L. Nyberg, Russel A. Shatford, Madhusudan V. Peshwa, James G. White, Frank B. Cerra, Wei‐Shou Hu
Abstract
We have developed a hepatocyte entrapment hollow fiber bioreactor for potential use as a bioartificial liver. Hepatocytes were entrapped in collagen gel inside the lumen of the hollow fibers. Medium was perfused through the intraluminal region after contraction of the hepatocyte-entrapment gel. Another medium stream, comparable to the patient's blood during clinical application, passed through the extracapillary space. Viability of hepatocytes remained high after 5 days as judged by the rate of oxygen uptake and viability staining. Urea and albumin synthetic activities were also sustained. Transmission electron microscopic examination demonstrated normal ultrastructural integrity of hepatocytes in such a bioreactor. With its sort-term, extracorporeal support of acute liver failure, the current bioreactor warrants further investigation.
OpenAlex reports 183 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have developed a hepatocyte entrapment hollow fiber bioreactor for potential use as a bioartificial liver. Hepatocytes were entrapped in collagen gel inside the lumen of the hollow fibers. Medium was perfused through the intraluminal region after contraction of the hepatocyte-entrapment gel. Another medium stream, comparable to the patient's blood during clinical application, passed through the extracapillary space. Viability of hepatocytes remained high after 5 days as judged by the rate of oxygen uptake and viability staining. Urea and albumin synthetic activities were also sustained. Transmission electron microscopic examination demonstrated normal ultrastructural integrity of hepatocytes in such a bioreactor. With its sort-term, extracorporeal support of acute liver failure, the current bioreactor warrants further investigation.
Key concepts: Bioartificial liver device, Bioreactor, Hepatocyte, Albumin, Chemistry, Chromatography, Biomedical engineering, Entrapment