2002The Journal of Korean Academy of Conservative DentistryOpen access

Microtensile bonding of one-step adhesives to smeared and non-smeared dentin

Yong-Beom Song, Jeong-Hee Jin, Se-Joon Lee, Kwang‐Won Lee

Open full text 0 citations

Abstract

The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wete treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37 distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(meanSD) of microtensile test were group 1, 25.694.31MPa; group 2, 40.9310.94MPa; group 3, 47.658.85MPa; group 4, 35.989.14MPa; group 5, 39.668.45MPa; group 6, 43.2613.01MPa; group 7, 25.074.2MPa;group 8, 30.44.74MPa;group 9, 33.617.88MPa. 2. One-Up Bond F was showed the highest value of 36.989.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.658.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p

About this research paper

What this paper is about

The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wete treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37 distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(meanSD) of microtensile test were group 1, 25.694.31MPa; group 2, 40.9310.94MPa; group 3, 47.658.85MPa; group 4, 35.989.14MPa; group 5, 39.668.45MPa; group 6, 43.2613.01MPa; group 7, 25.074.2MPa;group 8, 30.44.74MPa;group 9, 33.617.88MPa. 2. One-Up Bond F was showed the highest value of 36.989.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.658.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wete treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37 distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(meanSD) of microtensile test were group 1, 25.694.31MPa; group 2, 40.9310.94MPa; group 3, 47.658.85MPa; group 4, 35.989.14MPa; group 5, 39.668.45MPa; group 6, 43.2613.01MPa; group 7, 25.074.2MPa;group 8, 30.44.74MPa;group 9, 33.617.88MPa. 2. One-Up Bond F was showed the highest value of 36.989.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.658.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p

Key concepts: Bond strength, Dentin, Molar, Adhesive, Distilled water, Materials science, Composite material, Single bond

Related papers

Back to paper searchBrowse research topicsOriginal source
Microtensile bonding of one-step adhesives to smeared and non-smeared dentin — Research Paper | ScholarLens