2005•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Effects of birefringence on Fizeau interferometry that uses polarization phase shifting technique

Chunyu Zhao, Dongyel Kang, James H. Burge

Open publisher page 2 citations

Abstract

Interferometers that use different states of polarization for the reference and test beams can modulate the relative phase shift using polarization optics in the imaging system. This allows the interferometer to capture simultaneous images that have a fixed phase shift, which can be used for phase shifting interferometry. Since all measurements are made simultaneously, the interferometer is not sensitive to vibration. Fizeau interferometers of this type have advantage over Twyman-Green type systems because the optics are in the common path of both the reference and test wavefronts, therefore errors in these optics affect both wavefronts equally and do not limit the system accuracy. However, this is not strictly true for the polarization interferometer when both wavefronts are transmitted an optic that suffers from birefringence. If some of the components in the common path of the reference and test beams have residual birefringence, the two beams see different phases. Therefore, the interferometer is not strictly common path. As a result, an error can be introduced in the measurement. In this paper, we study the effect of birefringence on measurement accuracy when different polarization techniques are used in Fizeau interferometers. We demonstrate that measurement error is reduced dramatically for small amount of birefringence if the reference and test beams are circularly polarized rather than linearly polarized.

About this research paper

What this paper is about

Interferometers that use different states of polarization for the reference and test beams can modulate the relative phase shift using polarization optics in the imaging system. This allows the interferometer to capture simultaneous images that have a fixed phase shift, which can be used for phase shifting interferometry. Since all measurements are made simultaneously, the interferometer is not sensitive to vibration. Fizeau interferometers of this type have advantage over Twyman-Green type systems because the optics are in the common path of both the reference and test wavefronts, therefore errors in these optics affect both wavefronts equally and do not limit the system accuracy. However, this is not strictly true for the polarization interferometer when both wavefronts are transmitted an optic that suffers from birefringence. If some of the components in the common path of the reference and test beams have residual birefringence, the two beams see different phases. Therefore, the interferometer is not strictly common path. As a result, an error can be introduced in the measurement. In this paper, we study the effect of birefringence on measurement accuracy when different polarization techniques are used in Fizeau interferometers. We demonstrate that measurement error is reduced dramatically for small amount of birefringence if the reference and test beams are circularly polarized rather than linearly polarized.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Interferometers that use different states of polarization for the reference and test beams can modulate the relative phase shift using polarization optics in the imaging system. This allows the interferometer to capture simultaneous images that have a fixed phase shift, which can be used for phase shifting interferometry. Since all measurements are made simultaneously, the interferometer is not sensitive to vibration. Fizeau interferometers of this type have advantage over Twyman-Green type systems because the optics are in the common path of both the reference and test wavefronts, therefore errors in these optics affect both wavefronts equally and do not limit the system accuracy. However, this is not strictly true for the polarization interferometer when both wavefronts are transmitted an optic that suffers from birefringence. If some of the components in the common path of the reference and test beams have residual birefringence, the two beams see different phases. Therefore, the interferometer is not strictly common path. As a result, an error can be introduced in the measurement. In this paper, we study the effect of birefringence on measurement accuracy when different polarization techniques are used in Fizeau interferometers. We demonstrate that measurement error is reduced dramatically for small amount of birefringence if the reference and test beams are circularly polarized rather than linearly polarized.

Key concepts: Astronomical interferometer, Optics, Birefringence, Interferometry, Wavefront, Physics, Polarization (electrochemistry), Optical path

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of birefringence on Fizeau interferometry that uses polarization phase shifting technique — Research Paper | ScholarLens