2014•IEEE Transactions on Biomedical Circuits and SystemsRequires access

An ECG Recording Front-End With Continuous-Time Level-Crossing Sampling

Yongjia Li, Andre L. Mansano, Yuan Yuan, Duan Zhao, Wouter A. Serdijn

Open publisher page 65 citations

Abstract

An ECG recording front-end with a continuous- time asynchronous level-crossing analog-to-digital converter (LC-ADC) is proposed. The system is a voltage and current mixed-mode system, which comprises a low noise amplifier (LNA), a programmable voltage-to-current converter (PVCC) as a programmable gain amplifier (PGA) and an LC-ADC with calibration DACs and an RC oscillator. The LNA shows an input referred noise of 3.77 μVrms over 0.06 Hz-950 Hz bandwidth. The total harmonic distortion (THD) of the LNA is 0.15% for a 10 mVPP input. The ECG front-end consumes 8.49 μW from a 1 V supply and achieves an ENOB up to 8 bits. The core area of the proposed front-end is 690 ×710 μm2, fabricated in a 0.18 μm CMOS technology.

About this research paper

What this paper is about

An ECG recording front-end with a continuous- time asynchronous level-crossing analog-to-digital converter (LC-ADC) is proposed. The system is a voltage and current mixed-mode system, which comprises a low noise amplifier (LNA), a programmable voltage-to-current converter (PVCC) as a programmable gain amplifier (PGA) and an LC-ADC with calibration DACs and an RC oscillator. The LNA shows an input referred noise of 3.77 μVrms over 0.06 Hz-950 Hz bandwidth. The total harmonic distortion (THD) of the LNA is 0.15% for a 10 mVPP input. The ECG front-end consumes 8.49 μW from a 1 V supply and achieves an ENOB up to 8 bits. The core area of the proposed front-end is 690 ×710 μm2, fabricated in a 0.18 μm CMOS technology.

Why it matters

OpenAlex reports 65 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ECG recording front-end with a continuous- time asynchronous level-crossing analog-to-digital converter (LC-ADC) is proposed. The system is a voltage and current mixed-mode system, which comprises a low noise amplifier (LNA), a programmable voltage-to-current converter (PVCC) as a programmable gain amplifier (PGA) and an LC-ADC with calibration DACs and an RC oscillator. The LNA shows an input referred noise of 3.77 μVrms over 0.06 Hz-950 Hz bandwidth. The total harmonic distortion (THD) of the LNA is 0.15% for a 10 mVPP input. The ECG front-end consumes 8.49 μW from a 1 V supply and achieves an ENOB up to 8 bits. The core area of the proposed front-end is 690 ×710 μm2, fabricated in a 0.18 μm CMOS technology.

Key concepts: Effective number of bits, Programmable-gain amplifier, CMOS, Analog front-end, Total harmonic distortion, Electrical engineering, Front and back ends, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
An ECG Recording Front-End With Continuous-Time Level-Crossing Sampling — Research Paper | ScholarLens