1994ElectroanalysisRequires access

Observed redox interferences of poly(pyrrole)‐based perchlorate‐selective electrodes

Adam Hulanicki, Agata Michalska, Andrzej Lewenstam

Open publisher page 27 citations

Abstract

Abstract The responses of the poly(pyrrole)‐based ion‐selective perchlorate electrode were investigated in both perchlorate and redox buffers media. Sensitivity of tested electrodes both to the changes of perchlorate on concentrations and redox potential of the solution were observed. Slopes were characteristic −51.3 mV/dec in the case of perchlorate ion solutions and 61 mV/dec in the case of redox calibration. Potentiometric redox sensitivity of the tested poly(pyrrole) layers was observed in presence of 1 M sodium perchlorate. Potentiometric redox sensitivity of the bare platinum electrode and perchlorate‐sensitive electrode based on poly(pyrrole) in presence of 0.1 M NaClO4 were compared.

About this research paper

What this paper is about

Abstract The responses of the poly(pyrrole)‐based ion‐selective perchlorate electrode were investigated in both perchlorate and redox buffers media. Sensitivity of tested electrodes both to the changes of perchlorate on concentrations and redox potential of the solution were observed. Slopes were characteristic −51.3 mV/dec in the case of perchlorate ion solutions and 61 mV/dec in the case of redox calibration. Potentiometric redox sensitivity of the tested poly(pyrrole) layers was observed in presence of 1 M sodium perchlorate. Potentiometric redox sensitivity of the bare platinum electrode and perchlorate‐sensitive electrode based on poly(pyrrole) in presence of 0.1 M NaClO4 were compared.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The responses of the poly(pyrrole)‐based ion‐selective perchlorate electrode were investigated in both perchlorate and redox buffers media. Sensitivity of tested electrodes both to the changes of perchlorate on concentrations and redox potential of the solution were observed. Slopes were characteristic −51.3 mV/dec in the case of perchlorate ion solutions and 61 mV/dec in the case of redox calibration. Potentiometric redox sensitivity of the tested poly(pyrrole) layers was observed in presence of 1 M sodium perchlorate. Potentiometric redox sensitivity of the bare platinum electrode and perchlorate‐sensitive electrode based on poly(pyrrole) in presence of 0.1 M NaClO4 were compared.

Key concepts: Perchlorate, Redox, Sodium perchlorate, Potentiometric titration, Chemistry, Electrode, Inorganic chemistry, Platinum

Related papers

Back to paper searchBrowse research topicsOriginal source
Observed redox interferences of poly(pyrrole)‐based perchlorate‐selective electrodes — Research Paper | ScholarLens