2011Advances in Structural EngineeringRequires access

Development of New-Type Buckling-Restrained Braces and Their Application in Aseismic Steel Frameworks

Fei‐Fei Sun, Guo‐Qiang Li, Xiao-Kang Guo, Dazhu Hu, Baolin Hu

Open publisher page 20 citations

Abstract

Two new-type BRBs, i.e. TJI-type and TJII-type, were developed at Tongji University. TJI-type was designed for small load-carrying applications while TJII-type for large ones. Full scale cyclic test results demonstrated stable hysteretic behavior and substantial energy dissipation capacity of the new-type BRBs. Hysteretic model and stiffness equation were established for the new-type BRBs, being capable of simulating accurately experimental behavior of the BRBs under low cyclic loading. BRB-moment frames (BRBF) and ordinary concentrically braced frames (CBF) were compared by means of elasto-plastic seismic analysis on a typical 8-story building, showing that under severe earthquakes BRB acted as structural “fuse”, to protect beams and columns from significant yielding, while ordinary braces buckled, and led to large amount of plastic hinges occurring in beams and columns and inter-story drift larger than 1/50. As an alternative application of BRBs, the structural system of simple-connected steel frame with buckling restrained braces was proposed for multistory buildings. By non-linear static and time-history analysis, the seismic behavior of this system was investigated. The results showed that this system had energy-dissipation behavior as good as steel moment frame. The superiority of this system in terms of seismic performance under extremely severe earthquakes was also verified by shaking table test on a two-story full-scale structure.

About this research paper

What this paper is about

Two new-type BRBs, i.e. TJI-type and TJII-type, were developed at Tongji University. TJI-type was designed for small load-carrying applications while TJII-type for large ones. Full scale cyclic test results demonstrated stable hysteretic behavior and substantial energy dissipation capacity of the new-type BRBs. Hysteretic model and stiffness equation were established for the new-type BRBs, being capable of simulating accurately experimental behavior of the BRBs under low cyclic loading. BRB-moment frames (BRBF) and ordinary concentrically braced frames (CBF) were compared by means of elasto-plastic seismic analysis on a typical 8-story building, showing that under severe earthquakes BRB acted as structural “fuse”, to protect beams and columns from significant yielding, while ordinary braces buckled, and led to large amount of plastic hinges occurring in beams and columns and inter-story drift larger than 1/50. As an alternative application of BRBs, the structural system of simple-connected steel frame with buckling restrained braces was proposed for multistory buildings. By non-linear static and time-history analysis, the seismic behavior of this system was investigated. The results showed that this system had energy-dissipation behavior as good as steel moment frame. The superiority of this system in terms of seismic performance under extremely severe earthquakes was also verified by shaking table test on a two-story full-scale structure.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two new-type BRBs, i.e. TJI-type and TJII-type, were developed at Tongji University. TJI-type was designed for small load-carrying applications while TJII-type for large ones. Full scale cyclic test results demonstrated stable hysteretic behavior and substantial energy dissipation capacity of the new-type BRBs. Hysteretic model and stiffness equation were established for the new-type BRBs, being capable of simulating accurately experimental behavior of the BRBs under low cyclic loading. BRB-moment frames (BRBF) and ordinary concentrically braced frames (CBF) were compared by means of elasto-plastic seismic analysis on a typical 8-story building, showing that under severe earthquakes BRB acted as structural “fuse”, to protect beams and columns from significant yielding, while ordinary braces buckled, and led to large amount of plastic hinges occurring in beams and columns and inter-story drift larger than 1/50. As an alternative application of BRBs, the structural system of simple-connected steel frame with buckling restrained braces was proposed for multistory buildings. By non-linear static and time-history analysis, the seismic behavior of this system was investigated. The results showed that this system had energy-dissipation behavior as good as steel moment frame. The superiority of this system in terms of seismic performance under extremely severe earthquakes was also verified by shaking table test on a two-story full-scale structure.

Key concepts: Structural engineering, Earthquake shaking table, Dissipation, Buckling, Stiffness, Plastic hinge, Type (biology), Fuse (electrical)

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of New-Type Buckling-Restrained Braces and Their Application in Aseismic Steel Frameworks — Research Paper | ScholarLens