1991Journal of Cataract & Refractive SurgeryRequires access

Clinical variability in keratometry, ultrasound biometry measurements, and emmetropic intraocular lens power calculation

Luisa Pierro, Giulio Modorati, R. Brancato

Open publisher page 34 citations

Abstract

We calculated inter-examiner and intra-examiner variability in keratometry and ultrasound biometry when performed by two different examiners. The potential effect on intraocular lens power calculation was also considered. Intra-examiner variability was statistically and clinically significant for axial measurements, particularly in eyes with axial length greater than 24 mm. Thus, variability in biometric examination affected the emmetropic intraocular lens power, especially in myopic eyes.

About this research paper

What this paper is about

We calculated inter-examiner and intra-examiner variability in keratometry and ultrasound biometry when performed by two different examiners. The potential effect on intraocular lens power calculation was also considered. Intra-examiner variability was statistically and clinically significant for axial measurements, particularly in eyes with axial length greater than 24 mm. Thus, variability in biometric examination affected the emmetropic intraocular lens power, especially in myopic eyes.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We calculated inter-examiner and intra-examiner variability in keratometry and ultrasound biometry when performed by two different examiners. The potential effect on intraocular lens power calculation was also considered. Intra-examiner variability was statistically and clinically significant for axial measurements, particularly in eyes with axial length greater than 24 mm. Thus, variability in biometric examination affected the emmetropic intraocular lens power, especially in myopic eyes.

Key concepts: Emmetropia, Keratometer, Intraocular lens, Ultrasound, Ophthalmology, Medicine, Intraocular lens power calculation, Optometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical variability in keratometry, ultrasound biometry measurements, and emmetropic intraocular lens power calculation — Research Paper | ScholarLens