2009The Astrophysical JournalOpen access

X-RAY MICROLENSING IN RXJ1131-1231 AND HE1104-1805

G. Chartas, C. S. Kochanek, Xinyu Dai, S. Poindexter, G. P. Garmire

Open full text 183 citations

Abstract

We present results from a monitoring campaign performed with the Chandra X-ray Observatory of the gravitationally lensed quasars RX J1131−1231 and HE 1104−1805. We detect significant X-ray variability in all images of both quasars. The flux variability detected in image A of RX J1131−1231 is of particular interest because of its high amplitude (a factor of ∼ 20). We interpret it as arising from microlensing since the variability is uncorrelated with that of the other images and the X-ray flux ratios show larger changes than the optical as we would expect for microlensing of the more compact X-ray emission regions. The differences between the X-ray and optical flux ratios of HE 1104−1805 are less dramatic, but there is no significant soft X-ray or dust absorption, implying the presence of X-ray microlensing in this system as well. Combining the X-ray data with the optical light curves we find that the X-ray emitting region of HE 1104−1805 is compact with a half-light radius ≲6 r g , where the gravitational radius is r g = 3.6 × 10 14 cm, thus placing significant constraints on AGN corona models. We also find that the microlensing in HE 1104−1805 favors mass models for the lens galaxy that are dominated by dark matter. Finally, we better characterize the massive foreground cluster near RX J1131−1231, set limits on other sources of extended X-ray emission, and limit the fluxes of any central odd images to be 30–50 (3σ) times fainter than the observed images.

Open-access reader

About this research paper

What this paper is about

We present results from a monitoring campaign performed with the Chandra X-ray Observatory of the gravitationally lensed quasars RX J1131−1231 and HE 1104−1805. We detect significant X-ray variability in all images of both quasars. The flux variability detected in image A of RX J1131−1231 is of particular interest because of its high amplitude (a factor of ∼ 20). We interpret it as arising from microlensing since the variability is uncorrelated with that of the other images and the X-ray flux ratios show larger changes than the optical as we would expect for microlensing of the more compact X-ray emission regions. The differences between the X-ray and optical flux ratios of HE 1104−1805 are less dramatic, but there is no significant soft X-ray or dust absorption, implying the presence of X-ray microlensing in this system as well. Combining the X-ray data with the optical light curves we find that the X-ray emitting region of HE 1104−1805 is compact with a half-light radius ≲6 r g , where the gravitational radius is r g = 3.6 × 10 14 cm, thus placing significant constraints on AGN corona models. We also find that the microlensing in HE 1104−1805 favors mass models for the lens galaxy that are dominated by dark matter. Finally, we better characterize the massive foreground cluster near RX J1131−1231, set limits on other sources of extended X-ray emission, and limit the fluxes of any central odd images to be 30–50 (3σ) times fainter than the observed images.

Why it matters

OpenAlex reports 183 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present results from a monitoring campaign performed with the Chandra X-ray Observatory of the gravitationally lensed quasars RX J1131−1231 and HE 1104−1805. We detect significant X-ray variability in all images of both quasars. The flux variability detected in image A of RX J1131−1231 is of particular interest because of its high amplitude (a factor of ∼ 20). We interpret it as arising from microlensing since the variability is uncorrelated with that of the other images and the X-ray flux ratios show larger changes than the optical as we would expect for microlensing of the more compact X-ray emission regions. The differences between the X-ray and optical flux ratios of HE 1104−1805 are less dramatic, but there is no significant soft X-ray or dust absorption, implying the presence of X-ray microlensing in this system as well. Combining the X-ray data with the optical light curves we find that the X-ray emitting region of HE 1104−1805 is compact with a half-light radius ≲6 r g , where the gravitational radius is r g = 3.6 × 10 14 cm, thus placing significant constraints on AGN corona models. We also find that the microlensing in HE 1104−1805 favors mass models for the lens galaxy that are dominated by dark matter. Finally, we better characterize the massive foreground cluster near RX J1131−1231, set limits on other sources of extended X-ray emission, and limit the fluxes of any central odd images to be 30–50 (3σ) times fainter than the observed images.

Key concepts: Physics, Gravitational microlensing, Astrophysics, Astronomy, Stars

Related papers

Back to paper searchBrowse research topicsOriginal source
X-RAY MICROLENSING IN RXJ1131-1231 AND HE1104-1805 — Research Paper | ScholarLens