1958American Journal of PhysicsRequires access

Elliptic Polarimeter for the Student Laboratory: “Specimens” of Elliptically Polarized Light

Thomas Brown

Open publisher page 1 citations

Abstract

The elliptic polarimeter here described for use in the advanced undergraduate laboratory is simple and inexpensive, yet its precision approaches that of a research instrument. Experiments with it are simplified by providing the student with “specimens” of elliptically polarized light made by binding together with suitable orientation a Polaroid and a birefringent plate of approximately quarter-wave retardation. Precision is attained by means of an improved form of analyzer. The errors encountered with a compensator plate that does not produce exactly quarter-wave retardation are analyzed and a method for taking data is developed which reduces the final errors to small second-order terms.

About this research paper

What this paper is about

The elliptic polarimeter here described for use in the advanced undergraduate laboratory is simple and inexpensive, yet its precision approaches that of a research instrument. Experiments with it are simplified by providing the student with “specimens” of elliptically polarized light made by binding together with suitable orientation a Polaroid and a birefringent plate of approximately quarter-wave retardation. Precision is attained by means of an improved form of analyzer. The errors encountered with a compensator plate that does not produce exactly quarter-wave retardation are analyzed and a method for taking data is developed which reduces the final errors to small second-order terms.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The elliptic polarimeter here described for use in the advanced undergraduate laboratory is simple and inexpensive, yet its precision approaches that of a research instrument. Experiments with it are simplified by providing the student with “specimens” of elliptically polarized light made by binding together with suitable orientation a Polaroid and a birefringent plate of approximately quarter-wave retardation. Precision is attained by means of an improved form of analyzer. The errors encountered with a compensator plate that does not produce exactly quarter-wave retardation are analyzed and a method for taking data is developed which reduces the final errors to small second-order terms.

Key concepts: Polarimeter, Waveplate, Elliptical polarization, Physics, Birefringence, Optics, Polarimetry, Polarization (electrochemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Elliptic Polarimeter for the Student Laboratory: “Specimens” of Elliptically Polarized Light — Research Paper | ScholarLens