In order to obtain the thermal comfort work environment, the distribution of temperature and airflow velocity in typical computer room of school building is discussed with different supply air angles and velocities of incidence by CFD model. The calculated temperature after cooling in the room has a good agreement with the measured value. Furthermore, the distribution of temperature and airflow is uniform and the environment is comfort for working with supply air angles and velocity of incidence 45° and 60° and supply air velocity of incidence 1m/s comparing with that of other parameters. Additionally, the change of temperature becomes slow down with the increment of time and the air-conditioning has less influence on the change of temperature after about 900s with supply air angle and velocity of incidence 45°and 1m/s, respectively. The research is of great significance both in theory and practice to design air conditioning systems and evaluate the thermal comfort conditions.

About this research paper

What this paper is about

In order to obtain the thermal comfort work environment, the distribution of temperature and airflow velocity in typical computer room of school building is discussed with different supply air angles and velocities of incidence by CFD model. The calculated temperature after cooling in the room has a good agreement with the measured value. Furthermore, the distribution of temperature and airflow is uniform and the environment is comfort for working with supply air angles and velocity of incidence 45° and 60° and supply air velocity of incidence 1m/s comparing with that of other parameters. Additionally, the change of temperature becomes slow down with the increment of time and the air-conditioning has less influence on the change of temperature after about 900s with supply air angle and velocity of incidence 45°and 1m/s, respectively. The research is of great significance both in theory and practice to design air conditioning systems and evaluate the thermal comfort conditions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to obtain the thermal comfort work environment, the distribution of temperature and airflow velocity in typical computer room of school building is discussed with different supply air angles and velocities of incidence by CFD model. The calculated temperature after cooling in the room has a good agreement with the measured value. Furthermore, the distribution of temperature and airflow is uniform and the environment is comfort for working with supply air angles and velocity of incidence 45° and 60° and supply air velocity of incidence 1m/s comparing with that of other parameters. Additionally, the change of temperature becomes slow down with the increment of time and the air-conditioning has less influence on the change of temperature after about 900s with supply air angle and velocity of incidence 45°and 1m/s, respectively. The research is of great significance both in theory and practice to design air conditioning systems and evaluate the thermal comfort conditions.

Key concepts: Airflow, Thermal comfort, Air conditioning, Computational fluid dynamics, Room air distribution, Thermal, Air velocity, Air temperature

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Thermal Comfort in an Air Conditioning Room Using a CFD Model — Research Paper | ScholarLens