1996Analytical LettersRequires access

Adsorptive Cathodic Stripping Voltammetric Determination of Hexavalent Chromium

Mahmoud A. Ghandour, S. A. El-Shatoury, Azza M.M. Aly, S. M. Ahmed

Open publisher page 25 citations

Abstract

A sensitive and selective voltammetric method of analysis is developed for determination of trace amounts of Cr(VI) ions in neutral nitrate phosphate media. This method is based on controlled adsorptive preconcentration of chromium species at Hanging Mercury Drop Electrode (HMDE). The adsorptive stripping response was evaluated with respect to preconcentration time and potential and dependence on composition of supporting electrolyte. As low as 5x10−9 mol L−1 (0.25 μg/L) and 1x109 mol L−1 (0.52 μg/L) Cr(VI) can be detected using Cathodic Linear Sweep Stripping Voltammetry (CLSSV) and Differential Pulse Cathodic Stripping Voltammetry (DPCSV), respectively. The precision of the method is satisfactory with a relative deviation of 1.24% with ten experiments at the 0.52 μg 1−1 Cr(VI) level. The effect of various cations, anions and surface active substances (SAS) in synthetic aqueous samples has been investigated.

About this research paper

What this paper is about

A sensitive and selective voltammetric method of analysis is developed for determination of trace amounts of Cr(VI) ions in neutral nitrate phosphate media. This method is based on controlled adsorptive preconcentration of chromium species at Hanging Mercury Drop Electrode (HMDE). The adsorptive stripping response was evaluated with respect to preconcentration time and potential and dependence on composition of supporting electrolyte. As low as 5x10−9 mol L−1 (0.25 μg/L) and 1x109 mol L−1 (0.52 μg/L) Cr(VI) can be detected using Cathodic Linear Sweep Stripping Voltammetry (CLSSV) and Differential Pulse Cathodic Stripping Voltammetry (DPCSV), respectively. The precision of the method is satisfactory with a relative deviation of 1.24% with ten experiments at the 0.52 μg 1−1 Cr(VI) level. The effect of various cations, anions and surface active substances (SAS) in synthetic aqueous samples has been investigated.

Why it matters

OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive and selective voltammetric method of analysis is developed for determination of trace amounts of Cr(VI) ions in neutral nitrate phosphate media. This method is based on controlled adsorptive preconcentration of chromium species at Hanging Mercury Drop Electrode (HMDE). The adsorptive stripping response was evaluated with respect to preconcentration time and potential and dependence on composition of supporting electrolyte. As low as 5x10−9 mol L−1 (0.25 μg/L) and 1x109 mol L−1 (0.52 μg/L) Cr(VI) can be detected using Cathodic Linear Sweep Stripping Voltammetry (CLSSV) and Differential Pulse Cathodic Stripping Voltammetry (DPCSV), respectively. The precision of the method is satisfactory with a relative deviation of 1.24% with ten experiments at the 0.52 μg 1−1 Cr(VI) level. The effect of various cations, anions and surface active substances (SAS) in synthetic aqueous samples has been investigated.

Key concepts: Chemistry, Hanging mercury drop electrode, Cathodic stripping voltammetry, Adsorptive stripping voltammetry, Stripping (fiber), Hexavalent chromium, Chromium, Voltammetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Adsorptive Cathodic Stripping Voltammetric Determination of Hexavalent Chromium — Research Paper | ScholarLens