2014Journal of Breath ResearchOpen access

Analysis of human breath samples using a modified thermal desorption: gas chromatography electrospray ionization interface

James C. Reynolds, Modupe Jimoh, Cristina Guallar-Hoyas, Colin S. Creaser, Salman Siddiqui, C. L. Paul Thomas

Open full text 29 citations

Abstract

A two-stage thermal desorption/secondary electrospray ionization/time-of-flight mass spectrometry for faster targeted breath profiling has been studied. A new secondary electrospray ionization (SESI) source was devised to constrain the thermal desorption plume and promote efficient mixing in the ionization region. Further, a chromatographic pre-separation stage was introduced to suppress interferences from siloxanes associated with thermal desorption profiles of exhaled breath samples.In vitro tests with 5-nonanone indicated an increased sensitivity and a lowered limit-of-detection, both by a factor of ~4, the latter to an on-trap mass of 14.3 ng, equivalent to a sampled breath concentration of 967 pptv. Analysis of the mass spectrometric responses from 20 breath samples acquired sequentially from a single participant indicated enhanced reproducibility (reduced relative standard deviations (RSD) for 5-nonanone, benzaldehyde and 2-butanone were 28 %, 16% and 14% respectively. The corresponding values for an open SESI source were that 5-nonanone was not detected, with %RSD of 39% for benzaldehyde and 31% for 2-butanone).The constrained source with chromatographic pre-separation resulted in an increase in the number of detectable volatile organic compounds (VOCs) from 260 mass spectral peaks with an open SESI source to 541 peaks with the constrained source with pre-separation. Most of the observed VOCs were present at trace levels, at less than 2.5% of the intensity of the base peak.Seventeen 2.5 dm(3) distal breath samples were collected from asthma patients and healthy controls respectively, and subjected to comparative high-throughput screening using thermal desorption/SESI/time-of-flight mass spectrometry (TD-SESI-ToFMS). Breath metabolites were detected by using a background siloxane ion (hexamethylcyclotrisiloxane m/z 223.0642) as an internal lockmass. Eleven breath metabolites were selected from the breath research literature and successfully targeted. These data reinforce the proposition that TD-SESI-MS has potential for development as a rapid screening method for disease stratification and targeted metabolism profiling.

Open-access reader

About this research paper

What this paper is about

A two-stage thermal desorption/secondary electrospray ionization/time-of-flight mass spectrometry for faster targeted breath profiling has been studied. A new secondary electrospray ionization (SESI) source was devised to constrain the thermal desorption plume and promote efficient mixing in the ionization region. Further, a chromatographic pre-separation stage was introduced to suppress interferences from siloxanes associated with thermal desorption profiles of exhaled breath samples.In vitro tests with 5-nonanone indicated an increased sensitivity and a lowered limit-of-detection, both by a factor of ~4, the latter to an on-trap mass of 14.3 ng, equivalent to a sampled breath concentration of 967 pptv. Analysis of the mass spectrometric responses from 20 breath samples acquired sequentially from a single participant indicated enhanced reproducibility (reduced relative standard deviations (RSD) for 5-nonanone, benzaldehyde and 2-butanone were 28 %, 16% and 14% respectively. The corresponding values for an open SESI source were that 5-nonanone was not detected, with %RSD of 39% for benzaldehyde and 31% for 2-butanone).The constrained source with chromatographic pre-separation resulted in an increase in the number of detectable volatile organic compounds (VOCs) from 260 mass spectral peaks with an open SESI source to 541 peaks with the constrained source with pre-separation. Most of the observed VOCs were present at trace levels, at less than 2.5% of the intensity of the base peak.Seventeen 2.5 dm(3) distal breath samples were collected from asthma patients and healthy controls respectively, and subjected to comparative high-throughput screening using thermal desorption/SESI/time-of-flight mass spectrometry (TD-SESI-ToFMS). Breath metabolites were detected by using a background siloxane ion (hexamethylcyclotrisiloxane m/z 223.0642) as an internal lockmass. Eleven breath metabolites were selected from the breath research literature and successfully targeted. These data reinforce the proposition that TD-SESI-MS has potential for development as a rapid screening method for disease stratification and targeted metabolism profiling.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A two-stage thermal desorption/secondary electrospray ionization/time-of-flight mass spectrometry for faster targeted breath profiling has been studied. A new secondary electrospray ionization (SESI) source was devised to constrain the thermal desorption plume and promote efficient mixing in the ionization region. Further, a chromatographic pre-separation stage was introduced to suppress interferences from siloxanes associated with thermal desorption profiles of exhaled breath samples.In vitro tests with 5-nonanone indicated an increased sensitivity and a lowered limit-of-detection, both by a factor of ~4, the latter to an on-trap mass of 14.3 ng, equivalent to a sampled breath concentration of 967 pptv. Analysis of the mass spectrometric responses from 20 breath samples acquired sequentially from a single participant indicated enhanced reproducibility (reduced relative standard deviations (RSD) for 5-nonanone, benzaldehyde and 2-butanone were 28 %, 16% and 14% respectively. The corresponding values for an open SESI source were that 5-nonanone was not detected, with %RSD of 39% for benzaldehyde and 31% for 2-butanone).The constrained source with chromatographic pre-separation resulted in an increase in the number of detectable volatile organic compounds (VOCs) from 260 mass spectral peaks with an open SESI source to 541 peaks with the constrained source with pre-separation. Most of the observed VOCs were present at trace levels, at less than 2.5% of the intensity of the base peak.Seventeen 2.5 dm(3) distal breath samples were collected from asthma patients and healthy controls respectively, and subjected to comparative high-throughput screening using thermal desorption/SESI/time-of-flight mass spectrometry (TD-SESI-ToFMS). Breath metabolites were detected by using a background siloxane ion (hexamethylcyclotrisiloxane m/z 223.0642) as an internal lockmass. Eleven breath metabolites were selected from the breath research literature and successfully targeted. These data reinforce the proposition that TD-SESI-MS has potential for development as a rapid screening method for disease stratification and targeted metabolism profiling.

Key concepts: Desorption electrospray ionization, Extractive electrospray ionization, Chemistry, Thermal desorption, Electrospray ionization, Chromatography, Mass spectrometry, Desorption

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of human breath samples using a modified thermal desorption: gas chromatography electrospray ionization interface — Research Paper | ScholarLens