2014Circulation Arrhythmia and ElectrophysiologyRequires access

Nonfluoroscopic Catheter Visualization in Atrial Fibrillation Ablation

Philipp Sommer, Sascha Rolf, Christopher Piorkowski, Thomas Gaspar, Yan Huo, Carlos Piedra, Sergio Richter, Andreas Bollmann, Arash Arya, Gerhard Hindricks

Open publisher page 51 citations

Abstract

BACKGROUND: A technological platform (MediGuide) has been recently introduced for nonfluoroscopic catheter tracking. No data on the safety of this technology are yet available in a large cohort of patients. METHODS AND RESULTS: Data from a prospective ablation registry were analyzed. All patients undergoing atrial fibrillation ablation procedures supported by nonfluoroscopic catheter visualization technology were included. Patient characteristics and procedural data and complications within the first 3 months were recorded. Between May 2012 and February 2014, a total of 375 patients underwent atrial fibrillation ablation using nonfluoroscopic catheter visualization technology. The patients were predominantly men (68%); the majority were ablated for the first time (71%); left atrium was 43±6 mm; and left ventricular function was normal (59±9%). The median ablation procedure time was 135 (113-170) minutes, median fluoroscopy time 2.8 (1.5-4.4) minutes, and median radiation dose 789 (470-1466) cGy*cm(2). Regression analysis demonstrated a significant decrease of fluoroscopy time, dose, and procedure time. To confirm the result and show overall changes, the initial 50 cases (group 1) to the last 50 cases (group 2) of the series were compared: fluoroscopy time decreased from 6.0 (4.1-10.3) minutes in group 1 to 1.1 (0.7-1.5) minutes in group 2 and radiation dose from 2363 (1413-3475) to 490 (230-654) cGy*cm(2), respectively. Ten patients (2.7%) experienced complications: 5 cardiac tamponades (1.4%), 4 pseudoaneurysms (1.1%), and 1 stroke (0.3%). CONCLUSIONS: Atrial fibrillation ablation using the nonfluoroscopic catheter visualization technology is safe with a rate of complications of 2.7%. Procedure time (135 minutes) is not prolonged. A dramatic reduction in fluoroscopy time and dose was achieved.

About this research paper

What this paper is about

BACKGROUND: A technological platform (MediGuide) has been recently introduced for nonfluoroscopic catheter tracking. No data on the safety of this technology are yet available in a large cohort of patients. METHODS AND RESULTS: Data from a prospective ablation registry were analyzed. All patients undergoing atrial fibrillation ablation procedures supported by nonfluoroscopic catheter visualization technology were included. Patient characteristics and procedural data and complications within the first 3 months were recorded. Between May 2012 and February 2014, a total of 375 patients underwent atrial fibrillation ablation using nonfluoroscopic catheter visualization technology. The patients were predominantly men (68%); the majority were ablated for the first time (71%); left atrium was 43±6 mm; and left ventricular function was normal (59±9%). The median ablation procedure time was 135 (113-170) minutes, median fluoroscopy time 2.8 (1.5-4.4) minutes, and median radiation dose 789 (470-1466) cGy*cm(2). Regression analysis demonstrated a significant decrease of fluoroscopy time, dose, and procedure time. To confirm the result and show overall changes, the initial 50 cases (group 1) to the last 50 cases (group 2) of the series were compared: fluoroscopy time decreased from 6.0 (4.1-10.3) minutes in group 1 to 1.1 (0.7-1.5) minutes in group 2 and radiation dose from 2363 (1413-3475) to 490 (230-654) cGy*cm(2), respectively. Ten patients (2.7%) experienced complications: 5 cardiac tamponades (1.4%), 4 pseudoaneurysms (1.1%), and 1 stroke (0.3%). CONCLUSIONS: Atrial fibrillation ablation using the nonfluoroscopic catheter visualization technology is safe with a rate of complications of 2.7%. Procedure time (135 minutes) is not prolonged. A dramatic reduction in fluoroscopy time and dose was achieved.

Why it matters

OpenAlex reports 51 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: A technological platform (MediGuide) has been recently introduced for nonfluoroscopic catheter tracking. No data on the safety of this technology are yet available in a large cohort of patients. METHODS AND RESULTS: Data from a prospective ablation registry were analyzed. All patients undergoing atrial fibrillation ablation procedures supported by nonfluoroscopic catheter visualization technology were included. Patient characteristics and procedural data and complications within the first 3 months were recorded. Between May 2012 and February 2014, a total of 375 patients underwent atrial fibrillation ablation using nonfluoroscopic catheter visualization technology. The patients were predominantly men (68%); the majority were ablated for the first time (71%); left atrium was 43±6 mm; and left ventricular function was normal (59±9%). The median ablation procedure time was 135 (113-170) minutes, median fluoroscopy time 2.8 (1.5-4.4) minutes, and median radiation dose 789 (470-1466) cGy*cm(2). Regression analysis demonstrated a significant decrease of fluoroscopy time, dose, and procedure time. To confirm the result and show overall changes, the initial 50 cases (group 1) to the last 50 cases (group 2) of the series were compared: fluoroscopy time decreased from 6.0 (4.1-10.3) minutes in group 1 to 1.1 (0.7-1.5) minutes in group 2 and radiation dose from 2363 (1413-3475) to 490 (230-654) cGy*cm(2), respectively. Ten patients (2.7%) experienced complications: 5 cardiac tamponades (1.4%), 4 pseudoaneurysms (1.1%), and 1 stroke (0.3%). CONCLUSIONS: Atrial fibrillation ablation using the nonfluoroscopic catheter visualization technology is safe with a rate of complications of 2.7%. Procedure time (135 minutes) is not prolonged. A dramatic reduction in fluoroscopy time and dose was achieved.

Key concepts: Medicine, Atrial fibrillation, Catheter ablation, Ablation, Cardiology, Internal medicine, Catheter, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Nonfluoroscopic Catheter Visualization in Atrial Fibrillation Ablation — Research Paper | ScholarLens