2003•RadiologyRequires access

Respiration-induced Attenuation Artifact at PET/CT: Technical Considerations

Gerhard W. Goerres, Cyrill Burger, Ehab Mohamed Kamel, Burkhardt Seifert, Achim H. Kaim, Alfred Buck, Tobias C. Buehler, Gustav Konrad von Schulthess

Open publisher page 197 citations

Abstract

Combined positron emission tomographic (PET)/computed tomographic (CT) scanners allow the use of CT data for attenuation correction of PET images. Eight patients with cancer underwent PET/CT scanning. Transmission scanning was performed with conventional attenuation correction and with CT scanning during maximum inspiration and normal expiration. Image quality was visually compared and fluorine 18 activities were measured in volumes of interest in the lung and myocardium. Analysis of variance for repeated measures revealed a significant decrease (P =.0001) in measured activities between PET images corrected with CT data acquired during maximum inspiration and those corrected with the conventional attenuation correction method or with CT data acquired during normal expiration. Deep inspiration during CT can result in severe deterioration in the final PET image.

About this research paper

What this paper is about

Combined positron emission tomographic (PET)/computed tomographic (CT) scanners allow the use of CT data for attenuation correction of PET images. Eight patients with cancer underwent PET/CT scanning. Transmission scanning was performed with conventional attenuation correction and with CT scanning during maximum inspiration and normal expiration. Image quality was visually compared and fluorine 18 activities were measured in volumes of interest in the lung and myocardium. Analysis of variance for repeated measures revealed a significant decrease (P =.0001) in measured activities between PET images corrected with CT data acquired during maximum inspiration and those corrected with the conventional attenuation correction method or with CT data acquired during normal expiration. Deep inspiration during CT can result in severe deterioration in the final PET image.

Why it matters

OpenAlex reports 197 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Combined positron emission tomographic (PET)/computed tomographic (CT) scanners allow the use of CT data for attenuation correction of PET images. Eight patients with cancer underwent PET/CT scanning. Transmission scanning was performed with conventional attenuation correction and with CT scanning during maximum inspiration and normal expiration. Image quality was visually compared and fluorine 18 activities were measured in volumes of interest in the lung and myocardium. Analysis of variance for repeated measures revealed a significant decrease (P =.0001) in measured activities between PET images corrected with CT data acquired during maximum inspiration and those corrected with the conventional attenuation correction method or with CT data acquired during normal expiration. Deep inspiration during CT can result in severe deterioration in the final PET image.

Key concepts: Correction for attenuation, Medicine, Nuclear medicine, Artifact (error), Computed tomographic, Attenuation, Positron emission tomography, Expiration

Related papers

Back to paper searchBrowse research topicsOriginal source
Respiration-induced Attenuation Artifact at PET/CT: Technical Considerations — Research Paper | ScholarLens