2013•Unpublished venueRequires access

Rogowski coil with an active integrator for measurement of switching impulse current

Worrakan Limcharoen, Peerawut Yutthagowith

Open publisher page 21 citations

Abstract

This paper presents design and construction of an impulse current measuring system based on a Rogowski coil with various types of integrators, a conventional RC integrator, a compensated RC integrator, and an active integrator. The developed measuring systems were designed for measurement of switching impulse current waveform used in a residual voltage test of arresters. The comparative measurement of the Rogowski coil with those integrators and non-inductive shunt resistor were carried out in an HV Laboratory. From the experiment results measured by the same Rogowski coil with various integrators show that all current measuring systems provide accurate front time. The Rogowski coil with the conventional RC and compensated integrators provide inaccurate measurement of inverse current peak and tail time. The Rogowski coil with the active integrator provides all fairly accurate waveform parameters when it was compared to the measured results by the non-inductive shunt resistor.

About this research paper

What this paper is about

This paper presents design and construction of an impulse current measuring system based on a Rogowski coil with various types of integrators, a conventional RC integrator, a compensated RC integrator, and an active integrator. The developed measuring systems were designed for measurement of switching impulse current waveform used in a residual voltage test of arresters. The comparative measurement of the Rogowski coil with those integrators and non-inductive shunt resistor were carried out in an HV Laboratory. From the experiment results measured by the same Rogowski coil with various integrators show that all current measuring systems provide accurate front time. The Rogowski coil with the conventional RC and compensated integrators provide inaccurate measurement of inverse current peak and tail time. The Rogowski coil with the active integrator provides all fairly accurate waveform parameters when it was compared to the measured results by the non-inductive shunt resistor.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents design and construction of an impulse current measuring system based on a Rogowski coil with various types of integrators, a conventional RC integrator, a compensated RC integrator, and an active integrator. The developed measuring systems were designed for measurement of switching impulse current waveform used in a residual voltage test of arresters. The comparative measurement of the Rogowski coil with those integrators and non-inductive shunt resistor were carried out in an HV Laboratory. From the experiment results measured by the same Rogowski coil with various integrators show that all current measuring systems provide accurate front time. The Rogowski coil with the conventional RC and compensated integrators provide inaccurate measurement of inverse current peak and tail time. The Rogowski coil with the active integrator provides all fairly accurate waveform parameters when it was compared to the measured results by the non-inductive shunt resistor.

Key concepts: Rogowski coil, Integrator, Resistor, Waveform, Electromagnetic coil, Op amp integrator, Voltage, Passive integrator circuit