2009•Analytical ChemistryRequires access

Strategy of Accelerated Method Development for High-Throughput Bioanalytical Assays Using Ultra High-Performance Liquid Chromatography Coupled with Mass Spectrometry

Guowen Liu, Heidi M. Snapp, Qin C. Ji, Mark E. Arnold

Open publisher page 56 citations

Abstract

Here we report a strategy for rapid method development of high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with tandem mass spectrometry (uHPLC-MS/MS). First, a data set was established for the removal of representative phospholipids under different sample treatments to guide subsequent method development for various compounds. The recovery information of the analyte(s) of interest under different extraction conditions was then obtained during method development. With the recovery profiles and the pre-established knowledge of phospholipids removal in place, an optimal extraction condition was identified to give not only a satisfactory recovery but also a good cleanup of the sample. A rapid LC or uHPLC method was developed without the need of extensive column wash after the elution of the analyte. This strategy was demonstrated through the method development of a uHPLC-MS/MS bioanalytical assay for the quantitation of ketoconazole in human plasma with liquid-liquid extraction using a hexane and ethyl acetate solvent system. The retention time for ketoconazole through an isocratic elution was 18 s. Good accuracy and precision were obtained. Assay ruggedness was demonstrated by consistent internal standard responses and retention time for 500 sequential injections. In addition, consistent results were obtained for incurred sample reanalysis.

About this research paper

What this paper is about

Here we report a strategy for rapid method development of high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with tandem mass spectrometry (uHPLC-MS/MS). First, a data set was established for the removal of representative phospholipids under different sample treatments to guide subsequent method development for various compounds. The recovery information of the analyte(s) of interest under different extraction conditions was then obtained during method development. With the recovery profiles and the pre-established knowledge of phospholipids removal in place, an optimal extraction condition was identified to give not only a satisfactory recovery but also a good cleanup of the sample. A rapid LC or uHPLC method was developed without the need of extensive column wash after the elution of the analyte. This strategy was demonstrated through the method development of a uHPLC-MS/MS bioanalytical assay for the quantitation of ketoconazole in human plasma with liquid-liquid extraction using a hexane and ethyl acetate solvent system. The retention time for ketoconazole through an isocratic elution was 18 s. Good accuracy and precision were obtained. Assay ruggedness was demonstrated by consistent internal standard responses and retention time for 500 sequential injections. In addition, consistent results were obtained for incurred sample reanalysis.

Why it matters

OpenAlex reports 56 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Here we report a strategy for rapid method development of high-throughput bioanalytical assays using ultra high-performance liquid chromatography coupled with tandem mass spectrometry (uHPLC-MS/MS). First, a data set was established for the removal of representative phospholipids under different sample treatments to guide subsequent method development for various compounds. The recovery information of the analyte(s) of interest under different extraction conditions was then obtained during method development. With the recovery profiles and the pre-established knowledge of phospholipids removal in place, an optimal extraction condition was identified to give not only a satisfactory recovery but also a good cleanup of the sample. A rapid LC or uHPLC method was developed without the need of extensive column wash after the elution of the analyte. This strategy was demonstrated through the method development of a uHPLC-MS/MS bioanalytical assay for the quantitation of ketoconazole in human plasma with liquid-liquid extraction using a hexane and ethyl acetate solvent system. The retention time for ketoconazole through an isocratic elution was 18 s. Good accuracy and precision were obtained. Assay ruggedness was demonstrated by consistent internal standard responses and retention time for 500 sequential injections. In addition, consistent results were obtained for incurred sample reanalysis.

Key concepts: Chemistry, Bioanalysis, Chromatography, Throughput, Mass spectrometry, Liquid chromatography–mass spectrometry, High-performance liquid chromatography, Wireless

Related papers

Back to paper searchBrowse research topicsOriginal source
Strategy of Accelerated Method Development for High-Throughput Bioanalytical Assays Using Ultra High-Performance Liquid Chromatography Coupled with Mass Spectrometry — Research Paper | ScholarLens