2014•Analytical LettersRequires access

Determination of Titanium in Nano-Titanium(IV) Oxide Composite Food Packaging by Microwave Digestion and Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry

Qin‐Bao Lin, He Li, Huai‐Ning Zhong, Quan Zhao, Xiao Da-hui, Zhiwei Wang

Open publisher page 5 citations

Abstract

Titanium was determined in nano-titanium(IV) oxide food packaging by microwave digestion with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Microwave digestion was optimized using different acid combinations. Both spectrometry techniques showed good reproducibility, repeatability, and recovery. For ICP-AES, the limit of detection was 5.0 mg kg−1, the linear dynamic range was 100–5000 µ g L−1, the average recoveries for blank samples spiked with titanium were between 94.7% and 100.1%, and the relative standard deviations were from 2.1% to 7.1%. By ICP-MS, the limit of detection was 0.3 mg kg−1, the linear dynamic range was 0.5–200 µ g L−1, the recoveries were 88.4%–96.3%, and the relative standard deviations were 6.3%–7.4%. These results indicated that methods were effective for the determination of titanium in food packaging.

About this research paper

What this paper is about

Titanium was determined in nano-titanium(IV) oxide food packaging by microwave digestion with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Microwave digestion was optimized using different acid combinations. Both spectrometry techniques showed good reproducibility, repeatability, and recovery. For ICP-AES, the limit of detection was 5.0 mg kg−1, the linear dynamic range was 100–5000 µ g L−1, the average recoveries for blank samples spiked with titanium were between 94.7% and 100.1%, and the relative standard deviations were from 2.1% to 7.1%. By ICP-MS, the limit of detection was 0.3 mg kg−1, the linear dynamic range was 0.5–200 µ g L−1, the recoveries were 88.4%–96.3%, and the relative standard deviations were 6.3%–7.4%. These results indicated that methods were effective for the determination of titanium in food packaging.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Titanium was determined in nano-titanium(IV) oxide food packaging by microwave digestion with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Microwave digestion was optimized using different acid combinations. Both spectrometry techniques showed good reproducibility, repeatability, and recovery. For ICP-AES, the limit of detection was 5.0 mg kg−1, the linear dynamic range was 100–5000 µ g L−1, the average recoveries for blank samples spiked with titanium were between 94.7% and 100.1%, and the relative standard deviations were from 2.1% to 7.1%. By ICP-MS, the limit of detection was 0.3 mg kg−1, the linear dynamic range was 0.5–200 µ g L−1, the recoveries were 88.4%–96.3%, and the relative standard deviations were 6.3%–7.4%. These results indicated that methods were effective for the determination of titanium in food packaging.

Key concepts: Chemistry, Detection limit, Microwave digestion, Inductively coupled plasma mass spectrometry, Inductively coupled plasma, Mass spectrometry, Titanium, Repeatability

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Titanium in Nano-Titanium(IV) Oxide Composite Food Packaging by Microwave Digestion and Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry — Research Paper | ScholarLens