Ultrasonic Observation of the Nail Matrix
Takashi Hirai, Masatoshi Fumiiri
Abstract
Takashi Hirai, Masatoshi Fumiiri
Abstract
BACKGROUND: The authors made use of echograms for the observation of the nail matrix. OBJECTIVE: To inspect the nail matrix and identify what causes nail plate deformities. METHODS: A 30-MHz frequency high-resolution B-mode was applied to normal and damaged nails. RESULTS: Clear shadows of underlying nail plates were observed beneath the proximal nail fold. Some cases with nail plate deformities showed damaged sub-proximal fold nail plates, which would indicate nail matrix deformities. CONCLUSION: The echograms had diagnostic value to nail plate deformities. If a normal echogram is obtained at the proximal nail fold, the nail bed will be the place at which the nail deformities occur. If the echogram indicates any sub-proximal fold nail plate changes, the damaged nail matrix may be attributable to the nail deformities. Echograms also gave clear echoic shadows of subungual tumors. That contributed to identifying the infiltrating border of subungual malignant melanomas around the nail matrix noninvasively.
OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: The authors made use of echograms for the observation of the nail matrix. OBJECTIVE: To inspect the nail matrix and identify what causes nail plate deformities. METHODS: A 30-MHz frequency high-resolution B-mode was applied to normal and damaged nails. RESULTS: Clear shadows of underlying nail plates were observed beneath the proximal nail fold. Some cases with nail plate deformities showed damaged sub-proximal fold nail plates, which would indicate nail matrix deformities. CONCLUSION: The echograms had diagnostic value to nail plate deformities. If a normal echogram is obtained at the proximal nail fold, the nail bed will be the place at which the nail deformities occur. If the echogram indicates any sub-proximal fold nail plate changes, the damaged nail matrix may be attributable to the nail deformities. Echograms also gave clear echoic shadows of subungual tumors. That contributed to identifying the infiltrating border of subungual malignant melanomas around the nail matrix noninvasively.
Key concepts: Ultrasonic sensor, Nail (fastener), Matrix (chemical analysis), Nail matrix, Medicine, Computer science, Radiology, Surgery