Separation of Lipophilic Substances in Environmental Samples with Special Reference to Toxaphene
Samuel S. Atuma, Søren Krogh Jensen, Jacques Mowrer, Ulrika Örn
Abstract
Samuel S. Atuma, Søren Krogh Jensen, Jacques Mowrer, Ulrika Örn
Abstract
A microcolumn of alumina, activated at 250 degrees C over night and deactivated with 2% water in an oven at 150 degrees C, has shown better separation characteristics than similar ones, deactivated at room temperature, for a great number of organochlorine compounds, particularly with respect to multicomponent toxaphene and PCB. The microcolumn is a simple disposable Pasteur pipette. Three fractions are collected: one with PCB and DDE, one with toxaphene components having similar lipophilicity to DDT and the third, toxaphene components similar to DDD in lipophilicity. Two such toxaphene fractions give a better GLC-pattern than only one fraction. DDD and DDT, which interfere with the analysis of toxaphene can be eliminated, after their GLC analysis, from the "Toxaphene fractions" by nitration followed by reduction of the nitro compounds formed to their corresponding amines. Performance of the column using environmental samples showed that it is a useful tool in routine pesticide residue analysis, especially when toxaphene is present.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A microcolumn of alumina, activated at 250 degrees C over night and deactivated with 2% water in an oven at 150 degrees C, has shown better separation characteristics than similar ones, deactivated at room temperature, for a great number of organochlorine compounds, particularly with respect to multicomponent toxaphene and PCB. The microcolumn is a simple disposable Pasteur pipette. Three fractions are collected: one with PCB and DDE, one with toxaphene components having similar lipophilicity to DDT and the third, toxaphene components similar to DDD in lipophilicity. Two such toxaphene fractions give a better GLC-pattern than only one fraction. DDD and DDT, which interfere with the analysis of toxaphene can be eliminated, after their GLC analysis, from the "Toxaphene fractions" by nitration followed by reduction of the nitro compounds formed to their corresponding amines. Performance of the column using environmental samples showed that it is a useful tool in routine pesticide residue analysis, especially when toxaphene is present.
Key concepts: Toxaphene, Chemistry, Chromatography, Lipophilicity, Pesticide, Environmental chemistry, Organochlorine pesticide, Endrin