2000•Journal of Hand Surgery (European Volume)Requires access

Rapid Repeat Testing of Grip Strength for Detection of Faked Hand Weakness

M Tredgett, Tim R.C. Davis

Open publisher page 42 citations

Abstract

This study assessed the use of rapid, repeated measurement of grip strength to detect feigned hand weakness. Normal participants, performing with maximum effort or feigning hand weakness, and patients recovering from carpal tunnel surgery were asked to grip a Jamar dynamometer alternately with each hand on ten occasions. The results showed that grip strength fatigued by an average of 23% during the test in the normal participants, 18% in participants faking weakness, and increased by 2% in the carpal tunnel decompression patients. An increase in grip strength after the first effort was found in 39% of normal participants, 52% of participants faking hand weakness and in 69% of the carpal tunnel decompression patients. These results suggest that rapid, repeated measurement of grip strength is not a reliable discriminator of true and faked hand weakness.

About this research paper

What this paper is about

This study assessed the use of rapid, repeated measurement of grip strength to detect feigned hand weakness. Normal participants, performing with maximum effort or feigning hand weakness, and patients recovering from carpal tunnel surgery were asked to grip a Jamar dynamometer alternately with each hand on ten occasions. The results showed that grip strength fatigued by an average of 23% during the test in the normal participants, 18% in participants faking weakness, and increased by 2% in the carpal tunnel decompression patients. An increase in grip strength after the first effort was found in 39% of normal participants, 52% of participants faking hand weakness and in 69% of the carpal tunnel decompression patients. These results suggest that rapid, repeated measurement of grip strength is not a reliable discriminator of true and faked hand weakness.

Why it matters

OpenAlex reports 42 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study assessed the use of rapid, repeated measurement of grip strength to detect feigned hand weakness. Normal participants, performing with maximum effort or feigning hand weakness, and patients recovering from carpal tunnel surgery were asked to grip a Jamar dynamometer alternately with each hand on ten occasions. The results showed that grip strength fatigued by an average of 23% during the test in the normal participants, 18% in participants faking weakness, and increased by 2% in the carpal tunnel decompression patients. An increase in grip strength after the first effort was found in 39% of normal participants, 52% of participants faking hand weakness and in 69% of the carpal tunnel decompression patients. These results suggest that rapid, repeated measurement of grip strength is not a reliable discriminator of true and faked hand weakness.

Key concepts: Weakness, Grip strength, Medicine, Carpal tunnel syndrome, Physical therapy, Physical medicine and rehabilitation, Hand strength, Decompression