2013Inhalation ToxicologyRequires access

Comparison of dose-response relations between 4-week inhalation and intratracheal instillation of NiO nanoparticles using polimorphonuclear neutrophils in bronchoalveolar lavage fluid as a biomarker of pulmonary inflammation

Yohei Mizuguchi, Toshihiko Myojo, Takako Oyabu, Masayoshi Hashiba, Byeong Woo Lee, Makoto Yamamoto, Motoi Todoroki, Kenichiro Nishi, Chikara Kadoya, Akira Ogami, Yasuo Morimoto, Isamu Tanaka, Manabu Shimada, Kunio Uchida, Shigehisa Endoh, Junko Nakanishi

Open publisher page 24 citations

Abstract

Inhalation studies and intratracheal instillation studies using laboratory animals are commonly conducted for pulmonary toxicity tests of nanomaterials. In our study, male Wister rats were exposed to nickel oxide (NiO) particles including a nano-scale, even for aerosols and suspensions, in a 4-week inhalation and intratracheal instillation. Using polymorphonuclear neutrophils (PMNs) in bronchoalveolar lavage fluid as a biomarker of inflammation, we attempted to quantify the relationship between responses to inhalation and intratracheal instillation of the nanoparticles, based on surface area doses. Four kinds of NiO suspension samples with different specific surface areas were singly injected via the tracheas of the rats. The relationship between the instilled doses and PMN production was examined 3 days and 1 month after the instillation. In parallel, 4-week inhalation studies, using two of the suspensions, were conducted for aerosols generated by a pressurized nebulizer. NiO samples induced PMN responses 3 days after instillation according to the surface area doses, but not the mass doses, as has been reported in many studies. When the same NiO samples were tested in a 4-week inhalation and intratracheal instillation, the amount of pulmonary deposition of the sample after the 4-week inhalation, and an intratracheally instilled dose about ten-times higher, induced similar PMN responses 3 days after termination of inhalation and instillation. Using the relationship between these responses to 4-week inhalation and intratracheal instillation, it may be possible to estimate what aerosol concentrations of other nanomaterials might cause the same responses of PMN production as intratracheal instillation tests.

About this research paper

What this paper is about

Inhalation studies and intratracheal instillation studies using laboratory animals are commonly conducted for pulmonary toxicity tests of nanomaterials. In our study, male Wister rats were exposed to nickel oxide (NiO) particles including a nano-scale, even for aerosols and suspensions, in a 4-week inhalation and intratracheal instillation. Using polymorphonuclear neutrophils (PMNs) in bronchoalveolar lavage fluid as a biomarker of inflammation, we attempted to quantify the relationship between responses to inhalation and intratracheal instillation of the nanoparticles, based on surface area doses. Four kinds of NiO suspension samples with different specific surface areas were singly injected via the tracheas of the rats. The relationship between the instilled doses and PMN production was examined 3 days and 1 month after the instillation. In parallel, 4-week inhalation studies, using two of the suspensions, were conducted for aerosols generated by a pressurized nebulizer. NiO samples induced PMN responses 3 days after instillation according to the surface area doses, but not the mass doses, as has been reported in many studies. When the same NiO samples were tested in a 4-week inhalation and intratracheal instillation, the amount of pulmonary deposition of the sample after the 4-week inhalation, and an intratracheally instilled dose about ten-times higher, induced similar PMN responses 3 days after termination of inhalation and instillation. Using the relationship between these responses to 4-week inhalation and intratracheal instillation, it may be possible to estimate what aerosol concentrations of other nanomaterials might cause the same responses of PMN production as intratracheal instillation tests.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Inhalation studies and intratracheal instillation studies using laboratory animals are commonly conducted for pulmonary toxicity tests of nanomaterials. In our study, male Wister rats were exposed to nickel oxide (NiO) particles including a nano-scale, even for aerosols and suspensions, in a 4-week inhalation and intratracheal instillation. Using polymorphonuclear neutrophils (PMNs) in bronchoalveolar lavage fluid as a biomarker of inflammation, we attempted to quantify the relationship between responses to inhalation and intratracheal instillation of the nanoparticles, based on surface area doses. Four kinds of NiO suspension samples with different specific surface areas were singly injected via the tracheas of the rats. The relationship between the instilled doses and PMN production was examined 3 days and 1 month after the instillation. In parallel, 4-week inhalation studies, using two of the suspensions, were conducted for aerosols generated by a pressurized nebulizer. NiO samples induced PMN responses 3 days after instillation according to the surface area doses, but not the mass doses, as has been reported in many studies. When the same NiO samples were tested in a 4-week inhalation and intratracheal instillation, the amount of pulmonary deposition of the sample after the 4-week inhalation, and an intratracheally instilled dose about ten-times higher, induced similar PMN responses 3 days after termination of inhalation and instillation. Using the relationship between these responses to 4-week inhalation and intratracheal instillation, it may be possible to estimate what aerosol concentrations of other nanomaterials might cause the same responses of PMN production as intratracheal instillation tests.

Key concepts: Inhalation, Bronchoalveolar lavage, Intratracheal instillation, Inhalation exposure, Nebulizer, Pulmonary toxicity, Inflammation, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of dose-response relations between 4-week inhalation and intratracheal instillation of NiO nanoparticles using polimorphonuclear neutrophils in bronchoalveolar lavage fluid as a biomarker of pulmonary inflammation — Research Paper | ScholarLens