Spectrophotometric determination of thorium in food using 2-(2,5-disulfonic-4-methoxyphenylazo)-7-(2-hydroxyl-5-carboxylphenylazo)-1,8-dihydroxynaphthalene-3,6-disulfonic acid
Shenghao Meng, Mingliang Tian, Yuzhi Liu, Yong Guo, Yupeng Fan
Abstract
Shenghao Meng, Mingliang Tian, Yuzhi Liu, Yong Guo, Yupeng Fan
Abstract
A new highly sensitive and selective chromogenic reagent, 2-(2,5-disulfonic-4-methoxyphenylazo)-7-(2-hydroxyl-5-carboxylphenylazo)-1,8-dihydroxynaphthalene-3,6-disulfonic acid ( 1 ), was synthesized and applied to the spectrophotometric determination of trace thorium. In 5 mL of a 6 M perchloric acid medium, which greatly increases the selectivity, thorium reacts with 1 to form a 1: 2 green complex, having a sensitive absorption peak at 670 nm. Under optimal conditions, Beer’s law is obeyed over the range from 0 to 0.8 μg/mL Th(IV) and the apparent molar absorptivity is 2.09 × 10 5 L/mol cm. It is found that, uranium(VI), Ti(IV), heavy rare earths, and most of other common metal ions do not interfere. The method has been tested on the determination of thorium in food samples with satisfactory results.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new highly sensitive and selective chromogenic reagent, 2-(2,5-disulfonic-4-methoxyphenylazo)-7-(2-hydroxyl-5-carboxylphenylazo)-1,8-dihydroxynaphthalene-3,6-disulfonic acid ( 1 ), was synthesized and applied to the spectrophotometric determination of trace thorium. In 5 mL of a 6 M perchloric acid medium, which greatly increases the selectivity, thorium reacts with 1 to form a 1: 2 green complex, having a sensitive absorption peak at 670 nm. Under optimal conditions, Beer’s law is obeyed over the range from 0 to 0.8 μg/mL Th(IV) and the apparent molar absorptivity is 2.09 × 10 5 L/mol cm. It is found that, uranium(VI), Ti(IV), heavy rare earths, and most of other common metal ions do not interfere. The method has been tested on the determination of thorium in food samples with satisfactory results.
Key concepts: Chemistry, Thorium, Molar absorptivity, Chromogenic, Reagent, Perchloric acid, Uranium, Metal ions in aqueous solution