An assessment of oropharyngeal airway position using a fibreoptic bronchoscope
Shin Hyung Kim, J. E. Kim, Y. H. Kim, B. C. Kang, S. B. Heo, C. K. Kim, W. K. Park
Abstract
Open-access reader
Shin Hyung Kim, J. E. Kim, Y. H. Kim, B. C. Kang, S. B. Heo, C. K. Kim, W. K. Park
Abstract
Open-access reader
Selecting the appropriate oropharyngeal airway for safe and effective airway management is important in clinical practice. In this prospective observational study, we examined the position of the distal end of oropharyngeal airways using a fibreoptic bronchoscope. We enrolled 149 adults (72 men and 77 women). The correct airway size was determined by inserting four adult sizes Guedel airway (Hudson RCI; Teleflex Medical, Research Triangle, Park, NC, USA) (sizes 8, 9, 10 and 11) sequentially in anaesthetised patients. The 'best fit' airway was size 10 in 45 (62%) men, and size 9 in 58 (75%) women. However, when these airways were inserted, the distal end of the airway either touched or passed beyond the epiglottis tip in 20 (27%) men and six (8%) women, respectively. When a size-9 airway was inserted in men and a size-8 airway inserted in women, the distal ends were obstructed by the tongue in three (2%) patients. In conclusion, a size-9 airway in men and a size-8 airway in women are the most acceptable sizes for adults of average height.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Selecting the appropriate oropharyngeal airway for safe and effective airway management is important in clinical practice. In this prospective observational study, we examined the position of the distal end of oropharyngeal airways using a fibreoptic bronchoscope. We enrolled 149 adults (72 men and 77 women). The correct airway size was determined by inserting four adult sizes Guedel airway (Hudson RCI; Teleflex Medical, Research Triangle, Park, NC, USA) (sizes 8, 9, 10 and 11) sequentially in anaesthetised patients. The 'best fit' airway was size 10 in 45 (62%) men, and size 9 in 58 (75%) women. However, when these airways were inserted, the distal end of the airway either touched or passed beyond the epiglottis tip in 20 (27%) men and six (8%) women, respectively. When a size-9 airway was inserted in men and a size-8 airway inserted in women, the distal ends were obstructed by the tongue in three (2%) patients. In conclusion, a size-9 airway in men and a size-8 airway in women are the most acceptable sizes for adults of average height.
Key concepts: Medicine, Airway, Epiglottis, Airway management, Tongue, Anesthesia, Bronchoscopy, Surgery