2005EchocardiographyOpen access

Modified TEI Index: A Promising Parameter in Essential Hypertension?

Nurgül Keser, Sezai Yildiz, Nuri Kurtoğ, İsmet Dindar

Open full text 33 citations

Abstract

PURPOSE: Modified TEI index is pointed to be more effective in the evaluation of global cardiac functions compared to systolic and diastolic measurements alone. We planned to determine its applicability in hypertension and relation with left ventricular mass index (LVMI). METHODS: We studied 48 patients with mild/moderate hypertension and normal coronary angiograms. In total 22 patients (12 men, 10 women, mean age: 55 +/- 6) with normal LVMI were studied in group I, 26 patients (12 men, 14 women, mean age: 57 +/- 7) with increased LVMI in group II, and 20 patients (10 men, 10 women, mean age: 53 +/- 7) with normal blood pressure as a control group. Standard 2D, Doppler, and mitral annulus pulse wave tissue Doppler were used for all measurements. Modified TEI index was calculated as diastolic time interval measured from end of Am wave to origin of Em (a') minus systolic Sm duration (b') divided by b(a'-b'/b'). RESULTS: Modified TEI index was significantly higher in both groups than normal group and in group II than in group I. ( CONTROL GROUP: 0.33 +/- 0.05, group I: 0.51 +/- 0.17, group II: 0.68 +/- 0.16, P< 0.0001). CONCLUSION: Modified TEI index, a marker of left ventricular systolic and diastolic functions, is impaired in hypertensives before hypertrophy develops and impairment is more prominent in hypertrophy. Therefore, (1) modified TEI index in hypertensives is a safe, feasible, and sensitive index for evaluation of global ventricular functions. (2) Evaluation of hypertensives with this index periodically may guide interventions directed toward saving systolic and diastolic functions. (3) Modified TEI index is gaining importance as a complementary parameter to standard Doppler or in cases where standard Doppler has its limitations.

Open-access reader

About this research paper

What this paper is about

PURPOSE: Modified TEI index is pointed to be more effective in the evaluation of global cardiac functions compared to systolic and diastolic measurements alone. We planned to determine its applicability in hypertension and relation with left ventricular mass index (LVMI). METHODS: We studied 48 patients with mild/moderate hypertension and normal coronary angiograms. In total 22 patients (12 men, 10 women, mean age: 55 +/- 6) with normal LVMI were studied in group I, 26 patients (12 men, 14 women, mean age: 57 +/- 7) with increased LVMI in group II, and 20 patients (10 men, 10 women, mean age: 53 +/- 7) with normal blood pressure as a control group. Standard 2D, Doppler, and mitral annulus pulse wave tissue Doppler were used for all measurements. Modified TEI index was calculated as diastolic time interval measured from end of Am wave to origin of Em (a') minus systolic Sm duration (b') divided by b(a'-b'/b'). RESULTS: Modified TEI index was significantly higher in both groups than normal group and in group II than in group I. ( CONTROL GROUP: 0.33 +/- 0.05, group I: 0.51 +/- 0.17, group II: 0.68 +/- 0.16, P< 0.0001). CONCLUSION: Modified TEI index, a marker of left ventricular systolic and diastolic functions, is impaired in hypertensives before hypertrophy develops and impairment is more prominent in hypertrophy. Therefore, (1) modified TEI index in hypertensives is a safe, feasible, and sensitive index for evaluation of global ventricular functions. (2) Evaluation of hypertensives with this index periodically may guide interventions directed toward saving systolic and diastolic functions. (3) Modified TEI index is gaining importance as a complementary parameter to standard Doppler or in cases where standard Doppler has its limitations.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Modified TEI index is pointed to be more effective in the evaluation of global cardiac functions compared to systolic and diastolic measurements alone. We planned to determine its applicability in hypertension and relation with left ventricular mass index (LVMI). METHODS: We studied 48 patients with mild/moderate hypertension and normal coronary angiograms. In total 22 patients (12 men, 10 women, mean age: 55 +/- 6) with normal LVMI were studied in group I, 26 patients (12 men, 14 women, mean age: 57 +/- 7) with increased LVMI in group II, and 20 patients (10 men, 10 women, mean age: 53 +/- 7) with normal blood pressure as a control group. Standard 2D, Doppler, and mitral annulus pulse wave tissue Doppler were used for all measurements. Modified TEI index was calculated as diastolic time interval measured from end of Am wave to origin of Em (a') minus systolic Sm duration (b') divided by b(a'-b'/b'). RESULTS: Modified TEI index was significantly higher in both groups than normal group and in group II than in group I. ( CONTROL GROUP: 0.33 +/- 0.05, group I: 0.51 +/- 0.17, group II: 0.68 +/- 0.16, P< 0.0001). CONCLUSION: Modified TEI index, a marker of left ventricular systolic and diastolic functions, is impaired in hypertensives before hypertrophy develops and impairment is more prominent in hypertrophy. Therefore, (1) modified TEI index in hypertensives is a safe, feasible, and sensitive index for evaluation of global ventricular functions. (2) Evaluation of hypertensives with this index periodically may guide interventions directed toward saving systolic and diastolic functions. (3) Modified TEI index is gaining importance as a complementary parameter to standard Doppler or in cases where standard Doppler has its limitations.

Key concepts: Cardiology, Medicine, Internal medicine, Left ventricular hypertrophy, Diastole, Doppler imaging, Blood pressure, Essential hypertension