2010Molecular Imaging and BiologyOpen access

In Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation

Yujie Lu, Hidevaldo B. Machado, Qinan Bao, David Stout, Harvey Herschman, Arion F. Chatziioannou

Open full text 31 citations

Abstract

INTRODUCTION: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. METHODS: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. RESULTS: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. CONCLUSION: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP(3) approximation compared with the diffusion approximation.

Open-access reader

About this research paper

What this paper is about

INTRODUCTION: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. METHODS: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. RESULTS: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. CONCLUSION: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP(3) approximation compared with the diffusion approximation.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. METHODS: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. RESULTS: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. CONCLUSION: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP(3) approximation compared with the diffusion approximation.

Key concepts: Bioluminescence imaging, Bioluminescence, Positron emission tomography, Tomography, Tomographic reconstruction, Preclinical imaging, Molecular imaging, In vivo

Related papers