2008Review of Scientific InstrumentsOpen access

Unshielded fetal magnetocardiography system using two-dimensional gradiometers

Yusuke Seki, Akihiko Kandori, Yukio Kumagai, Mitsuru Ohnuma, Akihiko Ishiyama, Tetsuko Ishii, Yoshiyuki Nakamura, Hitoshi Horigome, Toshio Chiba

Open full text 15 citations

Abstract

We developed a fetal magnetocardiography (fMCG) system that uses a pair of two-dimensional gradiometers to achieve high signal-to-noise ratio. The gradiometer, which is based on a low-Tc superconducting quantum interference device, detects the gradient of a magnetic field in two orthogonal directions. Gradiometer position is easy to adjust by operating the gantry to drive the cryostat in both the swinging and axial directions. As a result, a fMCG waveform for 25 weeks' gestation was measured under an unshielded environment in real time. Moreover, the P and T waves for 25 and 34 weeks' gestation, respectively, were obtained by averaging. These results indicate that this two-dimensional gradiometer is one of the most promising techniques for measuring fetal heart rate and diagnosing fetal arrhythmia.

Open-access reader

About this research paper

What this paper is about

We developed a fetal magnetocardiography (fMCG) system that uses a pair of two-dimensional gradiometers to achieve high signal-to-noise ratio. The gradiometer, which is based on a low-Tc superconducting quantum interference device, detects the gradient of a magnetic field in two orthogonal directions. Gradiometer position is easy to adjust by operating the gantry to drive the cryostat in both the swinging and axial directions. As a result, a fMCG waveform for 25 weeks' gestation was measured under an unshielded environment in real time. Moreover, the P and T waves for 25 and 34 weeks' gestation, respectively, were obtained by averaging. These results indicate that this two-dimensional gradiometer is one of the most promising techniques for measuring fetal heart rate and diagnosing fetal arrhythmia.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We developed a fetal magnetocardiography (fMCG) system that uses a pair of two-dimensional gradiometers to achieve high signal-to-noise ratio. The gradiometer, which is based on a low-Tc superconducting quantum interference device, detects the gradient of a magnetic field in two orthogonal directions. Gradiometer position is easy to adjust by operating the gantry to drive the cryostat in both the swinging and axial directions. As a result, a fMCG waveform for 25 weeks' gestation was measured under an unshielded environment in real time. Moreover, the P and T waves for 25 and 34 weeks' gestation, respectively, were obtained by averaging. These results indicate that this two-dimensional gradiometer is one of the most promising techniques for measuring fetal heart rate and diagnosing fetal arrhythmia.

Key concepts: Magnetocardiography, Physics, Nuclear magnetic resonance, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Unshielded fetal magnetocardiography system using two-dimensional gradiometers — Research Paper | ScholarLens