2009Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineRequires access

The effect of tip geometry on the mechanical performance of unused and reprocessed orthopaedic drill bits

Kurosh Darvish, Mehdi Shafieian, Saqib Rehman

Open publisher page 9 citations

Abstract

Although reprocessed drill bits have been in clinical use as a cost-saving measure, their performance has not been critically evaluated in comparison with the performance of unused drill bits. The effect of three commonly used reprocessing methods on the geometry and mechanical performance of 2.5 mm orthopaedic drill bits was investigated and compared with that for unused drill bits. Four mechanically significant drill parameters including chisel edge, chisel edge angle, point angle, and lip length of 36 drill bits in four groups were measured and compared. Group A included unused drill bits. Group B included drill bits reprocessed once by one company whereas group C included those reprocessed twice by the same method. Group D included drill bits reprocessed once by another company. For mechanical performance, a test set-up was developed in which the time of travel of the drill bits through layers of cortical and trabecular synthetic bone materials under constant compressive force were measured. The geometrical parameters were found to be significantly altered as a result of the reprocessing methods. A linear relationship was derived to relate the chisel edge to the drill time through cortical and trabecular bones. The mechanical performance of drill bits is correlated largely to the chisel edge length. A larger chisel edge is correlated to a reduced drill time, particularly in the cortical bone.

About this research paper

What this paper is about

Although reprocessed drill bits have been in clinical use as a cost-saving measure, their performance has not been critically evaluated in comparison with the performance of unused drill bits. The effect of three commonly used reprocessing methods on the geometry and mechanical performance of 2.5 mm orthopaedic drill bits was investigated and compared with that for unused drill bits. Four mechanically significant drill parameters including chisel edge, chisel edge angle, point angle, and lip length of 36 drill bits in four groups were measured and compared. Group A included unused drill bits. Group B included drill bits reprocessed once by one company whereas group C included those reprocessed twice by the same method. Group D included drill bits reprocessed once by another company. For mechanical performance, a test set-up was developed in which the time of travel of the drill bits through layers of cortical and trabecular synthetic bone materials under constant compressive force were measured. The geometrical parameters were found to be significantly altered as a result of the reprocessing methods. A linear relationship was derived to relate the chisel edge to the drill time through cortical and trabecular bones. The mechanical performance of drill bits is correlated largely to the chisel edge length. A larger chisel edge is correlated to a reduced drill time, particularly in the cortical bone.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Although reprocessed drill bits have been in clinical use as a cost-saving measure, their performance has not been critically evaluated in comparison with the performance of unused drill bits. The effect of three commonly used reprocessing methods on the geometry and mechanical performance of 2.5 mm orthopaedic drill bits was investigated and compared with that for unused drill bits. Four mechanically significant drill parameters including chisel edge, chisel edge angle, point angle, and lip length of 36 drill bits in four groups were measured and compared. Group A included unused drill bits. Group B included drill bits reprocessed once by one company whereas group C included those reprocessed twice by the same method. Group D included drill bits reprocessed once by another company. For mechanical performance, a test set-up was developed in which the time of travel of the drill bits through layers of cortical and trabecular synthetic bone materials under constant compressive force were measured. The geometrical parameters were found to be significantly altered as a result of the reprocessing methods. A linear relationship was derived to relate the chisel edge to the drill time through cortical and trabecular bones. The mechanical performance of drill bits is correlated largely to the chisel edge length. A larger chisel edge is correlated to a reduced drill time, particularly in the cortical bone.

Key concepts: Chisel, Drill, Enhanced Data Rates for GSM Evolution, Drill bit, Drilling, Compression (physics), Mathematics, Geometry

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of tip geometry on the mechanical performance of unused and reprocessed orthopaedic drill bits — Research Paper | ScholarLens