1999•American Journal of RoentgenologyRequires access

Sonography in the diagnosis of carpal tunnel syndrome.

Iain Duncan, PATRICK P. SULLIVAN, Fred E. Lomas

Open publisher page 435 citations

Abstract

OBJECTIVE: The few papers published on the use of sonography in carpal tunnel syndrome suggest it may be a useful diagnostic test. This study aims to prospectively evaluate the use of sonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome. SUBJECTS AND METHODS: Patients with documented carpal tunnel syndrome and a group of asymptomatic control subjects were enrolled and underwent high-resolution sonography of the carpal tunnel. A small-footprint linear array transducer was used to scan and measure the median nerve cross-sectional area and the maximum transverse and anteroposterior diameters. Data from the patient group and the control group were compared to establish optimal diagnostic criteria for carpal tunnel syndrome. RESULTS: Sixty-eight carpal tunnel syndrome patients (50 women, 18 men) with 102 affected nerves and 68 nerves in 36 asymptomatic controls (23 women, 13 men) were examined. Qualitative assessment alone was found to be unreliable. All measurements showed significant differences between patients and controls. The most predictive measurement was swelling of the median nerve, which was significantly greater in carpal tunnel syndrome patients compared with controls (mean, 0.13 cm2 versus 0.07 cm2). Thus, quantitative assessment of the median nerve provides an accurate diagnostic test (sensitivity, 82%; specificity, 97%), with an area larger than 0.09 cm2 being highly predictive of carpal tunnel syndrome. CONCLUSION: We confirm that median nerve cross-sectional area measurement correlates well with the presence of carpal tunnel syndrome and is both sensitive and specific for the diagnosis.

About this research paper

What this paper is about

OBJECTIVE: The few papers published on the use of sonography in carpal tunnel syndrome suggest it may be a useful diagnostic test. This study aims to prospectively evaluate the use of sonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome. SUBJECTS AND METHODS: Patients with documented carpal tunnel syndrome and a group of asymptomatic control subjects were enrolled and underwent high-resolution sonography of the carpal tunnel. A small-footprint linear array transducer was used to scan and measure the median nerve cross-sectional area and the maximum transverse and anteroposterior diameters. Data from the patient group and the control group were compared to establish optimal diagnostic criteria for carpal tunnel syndrome. RESULTS: Sixty-eight carpal tunnel syndrome patients (50 women, 18 men) with 102 affected nerves and 68 nerves in 36 asymptomatic controls (23 women, 13 men) were examined. Qualitative assessment alone was found to be unreliable. All measurements showed significant differences between patients and controls. The most predictive measurement was swelling of the median nerve, which was significantly greater in carpal tunnel syndrome patients compared with controls (mean, 0.13 cm2 versus 0.07 cm2). Thus, quantitative assessment of the median nerve provides an accurate diagnostic test (sensitivity, 82%; specificity, 97%), with an area larger than 0.09 cm2 being highly predictive of carpal tunnel syndrome. CONCLUSION: We confirm that median nerve cross-sectional area measurement correlates well with the presence of carpal tunnel syndrome and is both sensitive and specific for the diagnosis.

Why it matters

OpenAlex reports 435 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The few papers published on the use of sonography in carpal tunnel syndrome suggest it may be a useful diagnostic test. This study aims to prospectively evaluate the use of sonographic measurements of the median nerve in the diagnosis of carpal tunnel syndrome. SUBJECTS AND METHODS: Patients with documented carpal tunnel syndrome and a group of asymptomatic control subjects were enrolled and underwent high-resolution sonography of the carpal tunnel. A small-footprint linear array transducer was used to scan and measure the median nerve cross-sectional area and the maximum transverse and anteroposterior diameters. Data from the patient group and the control group were compared to establish optimal diagnostic criteria for carpal tunnel syndrome. RESULTS: Sixty-eight carpal tunnel syndrome patients (50 women, 18 men) with 102 affected nerves and 68 nerves in 36 asymptomatic controls (23 women, 13 men) were examined. Qualitative assessment alone was found to be unreliable. All measurements showed significant differences between patients and controls. The most predictive measurement was swelling of the median nerve, which was significantly greater in carpal tunnel syndrome patients compared with controls (mean, 0.13 cm2 versus 0.07 cm2). Thus, quantitative assessment of the median nerve provides an accurate diagnostic test (sensitivity, 82%; specificity, 97%), with an area larger than 0.09 cm2 being highly predictive of carpal tunnel syndrome. CONCLUSION: We confirm that median nerve cross-sectional area measurement correlates well with the presence of carpal tunnel syndrome and is both sensitive and specific for the diagnosis.

Key concepts: Carpal tunnel syndrome, Medicine, Asymptomatic, Median nerve, Carpal tunnel, Surgery, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Sonography in the diagnosis of carpal tunnel syndrome. — Research Paper | ScholarLens