2001Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)Open access

Determination Method of Isocitric Acid in Food Additive Citric Acid.

Hiroko Kishi, Kiyoko Kawana

Open full text 1 citations

Abstract

A simple and rapid method using HPLC was developed for the determination of isocitric acid in food additive citric acid. One gram of sample was dissolved in 100 mL of water. HPLC separation was performed on an Inertsil ODS-3 column (4.6 mm i.d. x 250 mm) using 0.1% phosphoric acid as the mobile phase at a flow rate of 1 mL/min. Isocitric acid was detected at 210 nm. The calibration graph was rectilinear from 5 to 100 micrograms/mL. The recoveries of isocitric acid from sample at the levels of 0.1% and 0.4% were 98% and 99%, respectively, and the determination limit was 0.05%.

About this research paper

What this paper is about

A simple and rapid method using HPLC was developed for the determination of isocitric acid in food additive citric acid. One gram of sample was dissolved in 100 mL of water. HPLC separation was performed on an Inertsil ODS-3 column (4.6 mm i.d. x 250 mm) using 0.1% phosphoric acid as the mobile phase at a flow rate of 1 mL/min. Isocitric acid was detected at 210 nm. The calibration graph was rectilinear from 5 to 100 micrograms/mL. The recoveries of isocitric acid from sample at the levels of 0.1% and 0.4% were 98% and 99%, respectively, and the determination limit was 0.05%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and rapid method using HPLC was developed for the determination of isocitric acid in food additive citric acid. One gram of sample was dissolved in 100 mL of water. HPLC separation was performed on an Inertsil ODS-3 column (4.6 mm i.d. x 250 mm) using 0.1% phosphoric acid as the mobile phase at a flow rate of 1 mL/min. Isocitric acid was detected at 210 nm. The calibration graph was rectilinear from 5 to 100 micrograms/mL. The recoveries of isocitric acid from sample at the levels of 0.1% and 0.4% were 98% and 99%, respectively, and the determination limit was 0.05%.

Key concepts: Citric acid, Chromatography, Chemistry, Phosphoric acid, Calibration curve, High-performance liquid chromatography, Detection limit, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination Method of Isocitric Acid in Food Additive Citric Acid. — Research Paper | ScholarLens