2010•Journal of Analytical ChemistryRequires access

Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode

L. I. Skvortsova, O. V. Karunina, R. Yu. Bek

Open publisher page 5 citations

Abstract

A composition of quinhydrone and spectral graphite powders and also an epoxy resin with polyethylene polyamine as a binder is studied for fabricating a solid indicator electrode, renewed by mechanically cutting a thin surface layer, intended for measurements of the pH of solutions. It is shown that after the renewal of the electrode surface, the dissolution of the components of quinhydrone occurs in the near-electrode layer and the electrode potential depends on the pH of the solution and the time of the contact of the electrode with the solution. The pH dependence of potentials (E t ) at t = const in the pH range 2.0–7.0 is linear and close to the theoretical one. In the pH range 7.0–13.9, the results of measurements of E t by the proposed carbon-quinhydrone electrode, in contrast to the traditional quinhydrone electrode, are well reproducible and linearly depend on pH. This opens up the possibility of using the electrode for the determination of E t also in alkaline media.

About this research paper

What this paper is about

A composition of quinhydrone and spectral graphite powders and also an epoxy resin with polyethylene polyamine as a binder is studied for fabricating a solid indicator electrode, renewed by mechanically cutting a thin surface layer, intended for measurements of the pH of solutions. It is shown that after the renewal of the electrode surface, the dissolution of the components of quinhydrone occurs in the near-electrode layer and the electrode potential depends on the pH of the solution and the time of the contact of the electrode with the solution. The pH dependence of potentials (E t ) at t = const in the pH range 2.0–7.0 is linear and close to the theoretical one. In the pH range 7.0–13.9, the results of measurements of E t by the proposed carbon-quinhydrone electrode, in contrast to the traditional quinhydrone electrode, are well reproducible and linearly depend on pH. This opens up the possibility of using the electrode for the determination of E t also in alkaline media.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A composition of quinhydrone and spectral graphite powders and also an epoxy resin with polyethylene polyamine as a binder is studied for fabricating a solid indicator electrode, renewed by mechanically cutting a thin surface layer, intended for measurements of the pH of solutions. It is shown that after the renewal of the electrode surface, the dissolution of the components of quinhydrone occurs in the near-electrode layer and the electrode potential depends on the pH of the solution and the time of the contact of the electrode with the solution. The pH dependence of potentials (E t ) at t = const in the pH range 2.0–7.0 is linear and close to the theoretical one. In the pH range 7.0–13.9, the results of measurements of E t by the proposed carbon-quinhydrone electrode, in contrast to the traditional quinhydrone electrode, are well reproducible and linearly depend on pH. This opens up the possibility of using the electrode for the determination of E t also in alkaline media.

Key concepts: Quinhydrone electrode, Chemistry, Electrode, Reference electrode, Palladium-hydrogen electrode, Absolute electrode potential, Glass electrode, Standard hydrogen electrode

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode — Research Paper | ScholarLens